XE360™ Series User guide
• Schlage • OEM 200 Developer guide
Contents iv v vi vi FCC Statements IC Statements Contact information Warnings and cautions 7 Introduction 7 8 9 9 9 Lock diagrams Power Commissioning Lock modes Register a commerical construction credential 10 Diagnostics and Troubleshooting 11 11 11 Factory default reset (FDR) DPS (door position switch) REX (request for exit) 12 Troubleshooting 12 Factory default reset
Contents | FCC Statements FCC Statements FCC Compliance Statements • This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. • Changes or modifications not expressly approved by Schlage Lock Company could void the user's authority to operate the equipment.
Contents | IC Statements IC Statements IC Compliance Statements • • This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: 6. This device may not cause interference. 7. This device must accept any interference, including interference that may cause undesired operation of the device.
Contents | Contact information Contact information Should a system design engineer or developer need assistance, they should contact technical support at: Phone: 1-877-671-7011 www.allegion.com/us MIFARE® and DESFire™ are registered trademarks of NXP B.V. Warnings and cautions WARNING Warnings indicate potentially hazardous conditions, which if not avoided or corrected, may cause death or serious injury.
Introduction Lock diagrams XE360-EW Interior Exterior Battery compartment Button Communication area Exit device (not included) Lever XE360-M and XE360-T Interior Button or thumbturn (thumbturn shown) Exterior Communication area Lever Battery compartment 7 • Schlage • XE360 Locks user guide
Power XE360-EW Actual size XE360-M/XE360-T Screw retained in cover. Insert batteries as shown. Replace batteries as necessary after the low battery warning, or on a set schedule to ensure continuous operation. Î Use standard alkaline batteries. Lithium batteries are not recommended as there is little warning before the battery voltage is too low for continued operation.
Commissioning Commissioning is the process of adding the lock into the access control system. Once commissioned, the lock(s) can be controlled using Allegion Engage™. 1. Power the lock. The initiation sequence will begin. Wait for a steady blue light and one (1) beep. 2. Press and release the mode switch to enter manual commissioning mode. 3. Open the Engage Mobile Application and follow the steps to connect the lock. 4. The lock will blink one (1) long blue light when commissioning is complete.
Diagnostics and Troubleshooting Troubleshooting Problem Solution Manual commissioning failed. When commissioning fails, the lock will revert to FDR mode. Press and release the mode switch again to restart the process. • Confirm that bluetooth is enabled on the mobile device. • Confirm that the mobile device is not currently connected to another device. • Confirm that the lock is displaying steady blue LED. If not, restart the process by pressing and releasing the mode switch.
Diagnostics and Troubleshooting | Factory default reset (FDR) Lock indicators Function Actions Lights Beeps Contruction mode Mode initiated green on 1 Construction mode activated 5 green fast 1 Timeout 2 red long — Test mode Mode activated yellow on steady Manual commissioning mode Advertising blue on 1 MAPP connected 1 blue long — Door open 1 blue 1 Door closed 2 blue 2 REX closed 1 yellow fast 1 REX open 2 yellow fast 2 Internal push button (IPB) Door unlocked with I
Troubleshooting Troubleshooting Problem Solution Manual commissioning failed. When commissioning fails, the lock will revert to FDR mode. Press and release the mode switch again to restart the process. • Confirm that bluetooth is enabled on the mobile device. • Confirm that the mobile device is not currently connected to another device. • Confirm that the lock is displaying steady blue LED. If not, restart the process by pressing and releasing the mode switch.
About Allegion Allegion (NYSE: ALLE) is a global pioneer in seamless access, with leading brands like CISA®, Interflex®, LCN®, Schlage®, SimonsVoss® and Von Duprin®. Focusing on security around the door and adjacent areas, Allegion secures people and assets with a range of solutions for homes, businesses, schools and institutions. Allegion had $2.9 billion in revenue in 2019 and sells products in almost 130 countries. For more, visit www.allegion.com © 2023 Allegion 111850, Rev. 01/23 www.allegion.