6 INSPECTING THE PIPE SYSTEM FOR TIGHTNESS
Start the central unit with all wall inlets closed via the low voltage
connector (gure 1: 8) using a piece of metal wire. If air is still escaping
from the exhaust pipe after approximately 10 seconds, there is a leak
in the pipe system. The leak must be located and repaired. Do not run
the unit for more than 20 seconds with all of the wall inlets closed. If
the installation is completely airtight, the turbine will not receive any
air, therefore overheating and possibly incurring damage. The bypass
valve must be blocked for the duration of the inspection using a piece
of cardboard, for example (gure 2).
Fig. 3
7 ACCESSORIES
7.1 PRE-SEPARATORS
Pre-separator EE-20, steel. Product number 80603 / HVAC-code 6901215
Pre-separator EE-20, plastic. Product number 80604 / HVAC-code 6901216
The EE-20 is designed for vacuuming water, sand and coarse rubbish. If the pre-separator is equipped with
a dust bag, the EE-20 also enables the vacuuming of cooled-down ashes and ne dry dust.
Sticky substances and shards of glass may damage the pipe system. The system must
not be used for vacuuming liquids or substances other than normal dust unless a
suitable Allaway-pre-separator is used.
EN
7.2 DUST BAG INSTALLATION KITS
A-series (20l). Product number 81115 / HVAC-code 6901391
C-series (13l). Product number 81114 / HVAC-code 6901390
The central units can be equipped with a dust bag. Dust bag
installation kits are available from all leading retailers. Using a dust
bag is not obligatory, but it is recommended. Detailed instructions
for installation are supplied with the dust bag installation kit.
When using a dust bag installation kit (gure 3), the dust bag is
replaced and the lter serviced as follows:
Remove the dust bag (9), undo the mounting nut (6) located
underneath the lter, remove the dust bag rest (10) and detach
the lter (see section Servicing the Filter).
7.3 FILTER COVER FOR THE CENTRAL
UNIT
Filter Cover, 5 pcs/bag. Product number 80692 / HVAC-code
6901276
The filter cover (figure 4) facilitates cleaning the filter and
lengthens the maintenance intervals and life of the lter. Using
a lter cover is not obligatory, but it is recommended. Never
use a lter cover in central units that are equipped with a dust
bag. Filter covers are available from all leading retailers (sold in
bags of 5).
Fig. 3
6
10
9
Fig. 4