Installation guide
32
4 POWER CORD
If the power cord of the central unit has been damaged, it must be replaced with a special cord
compatible with the model of central unit in question and supplied by the manufacturer. Power cords
can be purchased from authorised Allaway service dealers.
5 USEFUL TIPS
5.1 WHAT TO DO IF THE CENTRAL UNIT WILL NOT START
n Check that the 230V power supply is intact.
n Check whether the central unit can be started from the other wall inlets.
n Check that the low voltage connector (fgure 1a; 8) is connected correctly to its counterpart on the
wall bracket of the central unit (C-serie) / Check the connection between the low voltage wires
and central unit (A-serie, gure 1b; 8).
nCheck whether the central unit can be started via the low voltage connector (gure 1a & 1b; 8) of
the central unit by closing the start circuit with a piece of metal wire.
n In case of suction hoses that are equipped with a handle start mechanism, check that the start
circuit of the hose is intact. If the central unit can be started by connecting the contact pins of a
wall inlet with a piece of metal wire, for example, but not with the control switch on the suction
hose handle, the fault is either in the hose or in the switch.
n If the central unit can be started via the low voltage connector but not by opening a wall inlet,
check that the low voltage wires are connected to the central unit and the wall inlets and that
there are no breaks in the wires.
nCheck whether the overheat protector inside the unit has tripped as a result of the turbine
overheating. If this is the case, wait for the turbine to cool down sufcienty (approximately 15
minutes) and then check that the lteris not blocked, the dust canister or the dust bag are not full,
and that there are no blockages in the wall inlets, the exhaust pipe or the cleaning accessories.
nCheck whether the overload protector of the electric motor has tripped. If this is the case, the
start relay of the central unit will make a clicking sound but the motor will not start; contact an
authorised Allaway service dealer.
5.2 WHAT TO DO IF SUCTION POWER HAS DROPPED
n Check that all other wall inlets are closed and that they do not leak.
n Check that there are no objects inside the wall inlet that could obstruct ow.
nCheck that the suction hose is intact, and that no objects that could obstruct ow are lodged in it.
nCheck that the dust canister is correctly in place and that the sealing materials of the dust canister
are clean and intact.
n Check that the dust canister is not full or that the dust bag does not require replacing.
n Check that the lter is in good condition.
n Check that the pipe system is airtight.
EN