Installation guide

32
4 POWER CORD
If the power cord of the central unit has been damaged, it must be replaced with a special cord
compatible with the model of central unit in question and supplied by the manufacturer. Power cords
can be purchased from authorised Allaway service dealers.
5 USEFUL TIPS
5.1 WHAT TO DO IF THE CENTRAL UNIT WILL NOT START
n Check that the 230V power supply is intact.
n Check whether the central unit can be started from the other wall inlets.
n Check that the low voltage connector (fgure 1a; 8) is connected correctly to its counterpart on the
wall bracket of the central unit (C-serie) / Check the connection between the low voltage wires
and central unit (A-serie, gure 1b; 8).
nCheck whether the central unit can be started via the low voltage connector (gure 1a & 1b; 8) of
the central unit by closing the start circuit with a piece of metal wire.
n In case of suction hoses that are equipped with a handle start mechanism, check that the start
circuit of the hose is intact. If the central unit can be started by connecting the contact pins of a
wall inlet with a piece of metal wire, for example, but not with the control switch on the suction
hose handle, the fault is either in the hose or in the switch.
n If the central unit can be started via the low voltage connector but not by opening a wall inlet,
check that the low voltage wires are connected to the central unit and the wall inlets and that
there are no breaks in the wires.
nCheck whether the overheat protector inside the unit has tripped as a result of the turbine
overheating. If this is the case, wait for the turbine to cool down sufcienty (approximately 15
minutes) and then check that the lteris not blocked, the dust canister or the dust bag are not full,
and that there are no blockages in the wall inlets, the exhaust pipe or the cleaning accessories.
nCheck whether the overload protector of the electric motor has tripped. If this is the case, the
start relay of the central unit will make a clicking sound but the motor will not start; contact an
authorised Allaway service dealer.
5.2 WHAT TO DO IF SUCTION POWER HAS DROPPED
n Check that all other wall inlets are closed and that they do not leak.
n Check that there are no objects inside the wall inlet that could obstruct ow.
nCheck that the suction hose is intact, and that no objects that could obstruct ow are lodged in it.
nCheck that the dust canister is correctly in place and that the sealing materials of the dust canister
are clean and intact.
n Check that the dust canister is not full or that the dust bag does not require replacing.
n Check that the lter is in good condition.
n Check that the pipe system is airtight.
EN