Installation guide

31
3 SAFETY DEVICES
The central units are equipped with safety devices that stop the unit in case of a
malfunction. If the issue causing the safety devices to trip is not resolved and the
system is used regardless of the malfunction, damage to the system may occur.
This is why the safety devices should not be considered as indicators of when the
dust canister requires emptying or when the lter needs servicing, or otherwise as
means of enabling the system to be used or installed in a manner contradictory to
the instructions.
3.1 OVERLOAD PROTECTOR
The central unit is equipped with an overload protector that stops the unit in case of an electrical
overload or malfunction. The overload protector cannot be reset and must be replaced by a qualied
electrical engineer. In connection with replacing the overload protector, the cause of tripping must be
investigated and resolved along with any other faults.
3.2 OVERHEAT PROTECTORS
The overheat protector of the turbine is located inside the unit and it stops the central unit in case
the turbine overheats. Wait until the turbine has cooled down and the overheat protector has been reset
(approximately 10-15 min.). Find out why the overheat protector has tripped and eliminate the cause (e.g.
full dust canister, blocked lter, blockage in the pipe system, wall inlet, exhaust pipe, cleaning accessories
or the blow-out grating). If whatever it is that causes the safety devices to trip is not resolved and the
system is used regardless of the malfunction, damage to the system may occur.
There are no parts for the user to maintain inside the central unit’s motor housing
(gure 1a; 7 / 1b;7, 9). We recommend that the need for maintenance and replacement
for the electric motor’s turbine and other parts inside the motor housing are
estimated by an authorised Allaway service dealer after approx. 600 hours of use.
This corresponds to approx. 8 years when the device is used an average of an hour
and a half per week.
EN
2.3 CLEANING ACCESSORIES
Tell children how to use the system and supervise them while they do so!
The speed and vacuum power of the airow in the suction hose and the nozzles
are great.
The cleaning accessories are subject to wear and tear according to the frequency of use and the oor
materials, and they must be replaced when necessary. Their life can be extended signicantly by cleaning
them from accumulated dirt after use and by storing them appropriately.
After vacuuming, detach the telescopic wand and the nozzles from the handle, and store them in the
nozzle holder with the brush of the oor/carpet nozzle retracted. Avoid storing the cleaning accessories
in direct sunlight, as long-term exposure to UV light makes the plastic parts, and especially the hose, go
brittle, thus shortening their serviceable life. Store the hose in the suction hose stand.
Separate instructions for use and maintenance are supplied with cleaning sets that are sold individually.
Remember the compatibility of the starting system and your central unit when you buy the cleaning