Thank you for your faith in our products!
We have produced these Instructions for Use and Maintenance so as to enable you to use your central
vacuum cleaning system in the best way possible. These instructions are meant for the central vacuum
cleaner models A 30, A 40, A 40 LCD and A 60. Nameplate markings (type): TE-1650-..-.., TE-1750-..-..,
TE-1950-..-.., VE-1750-..-.., VE-1950-..-.., V-2000-..-..
Please read the instructions carefully before using the system and follow all instructions in this manual. The
detailed installation instructions for the wall inlets and parts of the piping can be found in the installation
manual for the Allaway central vacuum cleaning system. You can ensure the operation, efciency, and
long service life of your central vacuum cleaning system by following all instructions and by only using
original Allaway parts and supplies. Keep the stickers from the product packaging to facilitate further
purchases and expansion of the system.
Keep the machine out of reach of small children. The machine is not a toy. The machine should not be
used by persons with reduced physical, sensory, or mental abilities. Monitor and instruct older children
and persons with insufcient experience or skills in the use of the machine.
1 GENERAL GUIDELINES
These central vacuum cleaners are only designed for domestic use and should only be used by one
person at a time and only for cleaning normal dust and rubbish.
Prior to starting up the unit for the rst time, please check that the dust canister is empty and that
the lter is in place.
If the central unit is used for vacuuming anything other than normal dust, a suitable Allaway pre
separator must be used (see section ACCESSORIES).
The wall inlets are equipped with catchers that stop large particles from entering the pipe system,
and longitudinal objects are caught in the steep elbow couplings located behind the inlets.
Only one wall inlet can be open at a time when the system is operational, and the covers of all
other inlets must be closed. Keeping more than one inlet open at a time weakens the suction power of
the system and increases the risk of blockages.
Please note that a separate instructions manual is available for the LCD displays of LCD central
units.
2 INSTALLATION
2.1 Positioning of the Central Unit
For detailed instructions for installation, please refer to the separate instructions for installing Allaway
central vacuum cleaning systems, which are supplied as standard with pipe kits PPK-44 and PPC-44
and can also be ordered separately. The instructions can also be found at our website at www.allaway.
.
Please follow local regulations for installations.
The central unit is connected to a 230 V power socket protected with a slow fuse of at least 10 A
or an automatic fuse of at least 16 A.
 The temperature of the room in which the central unit is located must not drop below +5 ° C or
rise above +35 °C, even while the unit is operational. The heat produced by the central unit is released
into the room. It is therefore important to ensure that air can circulate freely around the unit and
that the unit is not covered with textiles, for example, and that the room is adequately ventilated.
The central unit must not be installed in a cupboard or other tight spaces or in an unheated room.
Suitable rooms include storerooms and utility rooms.
Never store or handle ammable or corrosive materials in the room where the
central unit is located.
The exhaust pipe of the central unit is always led outside. We recommend that a mufer be tted
onto the exhaust pipe. The mufer should be positioned as close to the end of the exhaust pipe as
possible for maximum power. Mufers must not be installed on the suction side.
3 MAINTENANCE
3.1 Emptying the Dust Canister
The dust canister’s volume is approximately 20 litres.
The intervals for emptying the dust canister can be
established with experience. The guideline is that in
domestic use the dust canister should be emptied
every three months or so. The canister must be emptied
before the level of dust reaches the bottom of the quick
release clips. This helps to prevent dust seeping over the
edges of the canister in connection with emptying it.
Undo the quick release clips (1) of the dust canister. The
dust canister (5) is now suspended inside the central
unit. Lift the canister from the hooks and empty the
dust canister.
It is recommended that the dust canister and the sealing
cone be washed with a mild detergent once a year.
Make a note of any maintenance you perform in the
Maintenance Log on page 35 to help keep track of
maintenance intervals.
1
2
3
4
5
6
7
8
9
Figure 1