Installation manual
9
7 INSPECTING THE PIPE SYSTEM FOR 
TIGHTNESS
Start  the central unit with all  wall inlets closed  by  connecting 
the start circuit via the low voltage connector using a piece of 
metal wire. If  air is  still escaping  from the exhaust  pipe after 
approximately 10 seconds, there is a leak in the pipe system. 
The leak must be located and repaired. Do not run the unit for 
more than 20 seconds with all of the wall inlets closed. If the 
installation  is completely  airtight, the turbine  will not receive 
any air, therefore overheating and possibly incurring damage. The 
bypass valve must be blocked for the duration of the inspection 
using a piece of cardboard, for example (gure 4).
6 POWER CORD
If  the  power  cord  of  the  central  unit  has  been  damaged,  it  must  be  replaced  with  a  special  cord 
compatible with the model of central unit in question and supplied by the manufacturer. Power cords 
can be purchased from authorised Allaway service dealers.
8 EC DECLARATION OF CONFORMITY FOR ELECTRICAL SAFETY
Allaway Oy, Kangasvuorentie 32, 40340 Jyväskylä, Finland, hereby declares that
Central Vacuum Cleaners Type: TE-1650-..-.., TE-1750-..-.., TE-1950-..-.., VE-1750-..-.., VE-1950-..-.., V-2000-
..-..
have been manufactured in accordance with the relevant harmonised standards and fulls the essential 
requirements of the Low Voltage Directive (2006/95/EC) and the Electromagnetic Compatibility Directive 
(2004/108/EC).
5.5 Details Required for Maintenance Purposes
Prior to contacting an authorised Allaway service cleaner, note down 
the type and serial number (N:o) of your central unit, marked on the 
nameplate  (on the  external surface of the  central unit, on the  side  of 
the turbine housing).
Always keep the unit in its normal upright position during transportation 
and take care not to drop it or to make it subject to blows.
9 ACCESSORIES
9.1 Pre-separators
The EE-20 is designed for vacuuming liquids, sand and coarse rubbish. If the pre-separator is equipped 
with a dust bag, the EE-20 also enables the vacuuming of cooled-down ashes and ne dry dust.
Sticky substances and shards of glass may damage the pipe system. The system must 
not be  used  for  vacuuming liquids or substances  other  than  normal  dust  unless a 
suitable Allaway-pre-separator is used.
IPX2
Figure 4
Figure 4