7 INSPECTING THE PIPE SYSTEM FOR
TIGHTNESS
Start the central unit with all wall inlets closed by connecting
the start circuit via the low voltage connector using a piece of
metal wire. If air is still escaping from the exhaust pipe after
approximately 10 seconds, there is a leak in the pipe system.
The leak must be located and repaired. Do not run the unit for
more than 20 seconds with all of the wall inlets closed. If the
installation is completely airtight, the turbine will not receive
any air, therefore overheating and possibly incurring damage. The
bypass valve must be blocked for the duration of the inspection
using a piece of cardboard, for example (gure 4).
6 POWER CORD
If the power cord of the central unit has been damaged, it must be replaced with a special cord
compatible with the model of central unit in question and supplied by the manufacturer. Power cords
can be purchased from authorised Allaway service dealers.
8 EC DECLARATION OF CONFORMITY FOR ELECTRICAL SAFETY
Allaway Oy, Kangasvuorentie 32, 40340 Jyväskylä, Finland, hereby declares that
Central Vacuum Cleaners Type: TE-1650-..-.., TE-1750-..-.., TE-1950-..-.., VE-1750-..-.., VE-1950-..-.., V-2000-
..-..
have been manufactured in accordance with the relevant harmonised standards and fulls the essential
requirements of the Low Voltage Directive (2006/95/EC) and the Electromagnetic Compatibility Directive
(2004/108/EC).
5.5 Details Required for Maintenance Purposes
Prior to contacting an authorised Allaway service cleaner, note down
the type and serial number (N:o) of your central unit, marked on the
nameplate (on the external surface of the central unit, on the side of
the turbine housing).
Always keep the unit in its normal upright position during transportation
and take care not to drop it or to make it subject to blows.
9 ACCESSORIES
9.1 Pre-separators
The EE-20 is designed for vacuuming liquids, sand and coarse rubbish. If the pre-separator is equipped
with a dust bag, the EE-20 also enables the vacuuming of cooled-down ashes and ne dry dust.
Sticky substances and shards of glass may damage the pipe system. The system must
not be used for vacuuming liquids or substances other than normal dust unless a
suitable Allaway-pre-separator is used.
IPX2
Figure 4
Figure 4