INSTRUCTIONS FOR USE AND MAINTENANCE CENTRAL VACUUM CLEANERS A 30, A 40, A 40 LCD, A 60
CONTENTS 1 GENERAL GUIDELINES................................................................................................................................ 4 2 INSTALLATION............................................................................................................................................... 4 2.1 Positioning of the Central Unit................................................................................................................ 4 3 MAINTENANCE.............................
Thank you for your faith in our products! We have produced these Instructions for Use and Maintenance so as to enable you to use your central vacuum cleaning system in the best way possible. These instructions are meant for the central vacuum cleaner models A 30, A 40, A 40 LCD and A 60. Nameplate markings (type): TE-1650-..-.., TE-1750-..-.., TE-1950-..-.., VE-1750-..-.., VE-1950-..-.., V-2000-..-.. Please read the instructions carefully before using the system and follow all instructions in this manual.
The temperature of the room in which the central unit is located must not drop below +5 ° C or rise above +35 °C, even while the unit is operational. The heat produced by the central unit is released into the room. It is therefore important to ensure that air can circulate freely around the unit and that the unit is not covered with textiles, for example, and that the room is adequately ventilated. The central unit must not be installed in a cupboard or other tight spaces or in an unheated room.
3.2 Servicing the Filter (Figure 1) The central unit is equipped with a filter (2) that protects the turbine against dust. The filter must be intact and correctly in place. New filters can be purchased from all leading retailers and authorised Allaway service dealers. Unplug the power cord (6) from the wall socket. Remove and empty the dust canister (5). Remove the sealing cone (sealing and cone). Remove the filter cover carefully if the cover is in use.
The overheat protector of the turbine is located inside the unit and it stops the central unit in case the turbine overheats. Wait until the turbine has cooled down and the overheat protector has been reset (approximately 10-15 min.). Find out why the overheat protector has tripped and eliminate the cause (e.g. full dust canister, blocked filter, blockage in the pipe system, wall inlet, exhaust pipe, cleaning accessories or the blow-out grating).
5.2 What to Do if Suction Power Has Dropped Check that all other wall inlets are closed and that they do not leak. Check that there are no objects inside the wall inlet that could obstruct flow. Check that the suction hose is intact and that no objects that could obstruct flow are lodged in it. Check that the dust canister is correctly in place and that the sealing materials of the dust canister are clean and intact.
5.5 Details Required for Maintenance Purposes Prior to contacting an authorised Allaway service cleaner, note down the type and serial number (N:o) of your central unit, marked on the nameplate (on the external surface of the central unit, on the side of the turbine housing). IPX2 Always keep the unit in its normal upright position during transportation and take care not to drop it or to make it subject to blows.
9.2 Dust Bag Installation Kits The central units can be equipped with a dust bag. Dust bag installation kits are available from all leading retailers. Using a dust bag is not obligatory, but it is recommended. Detailed instructions for installation are supplied with the dust bag installation kit.
MAINTENANCE LOG Type ____________ Dust Canister Emptied or Dust Bag Replaced No.
Customer service Austria Provit Handels- u.Engineering GmbH, Laaberbachstrasse 18, A-4600 Wels phone: 43-7242-55 677, info@provit.at, www.provit.at Cyprus Domex Trading Co.Ltd, CTC House,Athalassa P.O.Box 21744, 1589 Nicosia phone: 357-22-74 03 40, domex@ctcgroup.com, www.ctcgroup.com Denmark BHC Teknik, Brystrupvej 4, Hellevad, 6230 Rødekro phone: 45-7466 9613, info@bhc-teknik.dk, www.bhc-teknik.