Installation (contd)
Supporting and Mounting
Mount the generator on a concrete slab capable of supporting the weight of the generator. The
slab must extend on all sides beyond the frame by at lea
st one foot. Contact a cement contractor
for slab specificatio
ns if necessary. Attach the frame to the concrete slab using 3/8” diameter
expa
nsion anchor bolts (not supplied).
Grounding
NOTE: IT IS RECOMMENDED THAT ONLY A TRAINED AND LICENSED
ELEC
TRICIAN PERFORM THIS PROCEDURE
Connect a #6 AWG ground
ing wire (not included) from the ground connector (8) on the generator
to a ground
ing rod (not included) that has been driven at least 24 inches deep into the earth. The
grounding rod must be an earth-driven copper or brass rod (electrode) which can adequately
ground the generator.