Operating instructions
Owner'sManual
Compressor(cont'd)
Maintenance(cont'd)
Draining the Tank
Relievetheairpressureinthesystemandopenthepetcockonthebottomofthetankto
drain.
WARNING! CONDENSATION WILLACCUMULATE IN THE TANK. TO
PREVENT CORROSIONOF THE TANKFROM THEINSIDE, THIS
MOISTURE MUSTBE DRAINED AT THEEND OF EVERY WORKDAY.BE
SURE TO WEARPROTECTIVE EYEWEAR_
Note: In cold climates, drain the tank after each use to reduce
problems with freezing of water condensation.
Checkingthe ReliefValve
Pull the reliefvalve daily to ensure that it is operatingproperlyand to clear
the valve of any possibleobstructions.
Testing for Leaks
Check that allconnections are tight.A small leak inany of the hoses or pipe
connections will substantially reduce the performance of your air compressor.
If you suspect a leak, spray a small amount of soapy water around the area
of the suspected leak with a spray bottle. If bubbles appear, repair or replace
the faulty component. Do not overtighten any connections.
Storage
Before storing the compressor for a prolonged period, use an air blow gun to
clean all dustand debrisfrom the STORAGE compressor.Disconnectthe
power cord and coil it up. Pullthe pressurereliefvalve to release all pressure
from the tank. Drainall moisturefrom the tank. Cover the entire unitto protect
it from moistureand dust.
Servicing
Perform the followingmaintenance at the intervalsindicated below:
• Operate the pressure relief valve: Daily
• Drain tank: Daily
24