AIR FLOW CONTROL
VALVE IS OPTIONAL
(USE TO MAINTAIN
MAXIMUM AIR
EFFICIENCY)
AIR FLOW CONTROL
VALVE PART NO:
13400-30
Muffler (air exhaust)
is supplied with
each pump.
DISCHARGE
Ports are on the end
SUCTION
Ports are on the end
Flexible Airline
SUCTION AND DISCHARGE PORTS CAN BE
REPOSITIONED TO SUIT THE APPLICATION
DIMENSIONS
Dimensions in inches and (mm)
PERFORMANCE CURVE
(Based on water-flooded suction)
SPECIFICATIONS
CAPACITY:
Adjustable 0-17 GPM (64,6 LPM)
MAXIMUM TEMP:
KT-05 model – 200˚F (93˚C)
Other models – 150˚F (66˚C)
MAXIMUM AIR PRESSURE:
120 psi (8,2 bar)
MINIMUM AIR PRESSURE:
20 psi (1,3 bar)
DRY LIFT:
Models with PTFE balls –
10 feet (3 meters)
Other models – 15 feet (4,5 meters)
WEIGHT:
PVDF models – 12 pounds (5,4 kg)
Other models – 9 pounds (4,1 kg)
MAXIMUM SOLIDS:
1/8 ˝ (3,2 mm) Ball Check Valve
3/8 ˝ (9,5 mm) Max-Pass Valve
AIR SUPPLY:
Inlet – 1/4 ˝ NPT Female (BSP compatible)
Outlet – 3/8˝ NPT Female
FLUID INLET/DISCHARGE:
1/2 ˝ NPS Female (NPT or BSP compatible)
2.00
(50.8)
11.36
(288.5)
6.35
(161.3)
4.86
(123.4)
AIR
EXHAUST
DO NOT USE AIR LINE LUBRICATION
Typical Installation
0 2 4 6 8 1012141618
DISCHARGE FLOW- Liters/Min.
120
(8,2)
100
(6,8)
80
(5,4)
60
(4,1)
40
(2,7)
20
(1,3)
PRESSURE INLET/OUTLET PSIG (BARS)
DISCHARGE FLOW- U.S. Gals./Min.
7,6 15,1 22,7 30,3 37,9 45,4 53,0 60,6 68,1
AIR CONSUMPTION - SCFM
5
TOTAL HEAD IN FEET (METERS)
276
(83,9)
230
(69,9)
184
(55,9)
138
(41,9)
92
(27,9)
46
(13,9)
15
10
2
12.04
(305.8)
6.81
(173.0)
10.12
(257.0)
6.13
(155.7)
AIR
INLET
DISCHARGE
SUCTION