User guide

DISCHARGE
SUCTION
Muffler (air exhaust)
is supplied with
each pump.
Flexible Airline
AIR INLET IS ON
SIDE WITH S.S.
INSERT AND
OPPOSITE AIR
VALVE ASSEMBLY
SUCTION AND DISCHARGE PORTS
CAN BE REPOSITIONED TO SUIT
THE APPLICATION
AIR FLOW CONTROL
VALVE IS OPTIONAL
(USE TO MAINTAIN
MAXIMUM AIR EFFICIENCY)
AIR FLOW CONTROL VALVE
PART NO: 13400-30
DO NOT USE AIR LINE LUBRICATION
DIMENSIONS
Dimensions in inches and (mm)
PERFORMANCE CURVE
(Based on water-flooded suction)
SPECIFICATIONS
CAPACITY:
Adjustable 0-9 GPM (34,0 LPM)
MAXIMUM TEMP:
PVDF models 200˚F (93˚C)
Other models 150˚F (66˚C)
MAXIMUM AIR PRESSURE:
120 psi (8,2 bar)
MINIMUM AIR PRESSURE:
20 psi (1,3 bar)
DRY LIFT:
Models with PTFE balls
10 feet (3 meters)
Models with Max-Pass valves
17 feet (5,2 meters)
012345678910
DISCHARGE FLOW- Liters/Min.
120
(8,2)
100
(6,8)
80
(5,4)
60
(4,1)
40
(2,7)
20
(1,3)
PRESSURE INLET/OUTLET PSIG (BAR)
DISCHARGE FLOW- U.S. Gals./Min.
3,8 7,6 11,4 15,1 18,9 22,7 26,5 30,3 34,1 37,9
3
TOTAL HEAD IN FEET (METERS)
276
(83,9)
230
(69,9)
184
(55,9)
138
(41,9)
92
(27,9)
46
(13,9)
10
6
AIR CONSUMPTION - SCFM
4.21
(106,9)
8.55
(217,2)
AIR
INLET
DISCHARGE
SUCTION
4.06
(103,1)
6.63
(168,4)
2.40
(61,0)
3.86
(98,0)
7.19
(182,6)
1.06
(26,9)
4.82
(122,4)
R .15
(3,8mm)
EXHAUST
FASTENER TORQUE REQUIREMENTS
NOTE: When reassembling, loosely tighten all external fasteners adjusting and
aligning. Then gradually, in an alternating fashion, tighten to the torque
requirements listed below.
AIR VALVE ASSEMBLY SCREWS 12 in-lbs (1,35 NM)
BAND CLAMPS 13.3 ft-lbs (18,8 NM)
MANIFOLD BOLTS, 10 in-lbs (1,13 NM)
OUTER DIAPHRAGM PLATES, 40 in-lbs (4,5 NM)
U.S. Patent Number 5232352
WEIGHT:
PVDF models 5 pounds (2,3 kg)
Other models 3.8 pounds (1,7 kg)
MAXIMUM SOLIDS:
Models with Max-Pass valves 1/4˝
(6,4 mm)
Other models 1/16˝ (3,2 mm)
AIR SUPPLY:
Inlet 1/4˝ NPS Female
(BSP or NPT compatible)
Outlet 3/8˝ NPS Female
(BSP or NPT compatible)
FLUID INLET/DISCHARGE:
3/8˝ NPS Female
(BSP or NPT compatible)
NOTE: AIR INLET IS ON THE SIDE WITH STAINLESS STEEL
INSERT. THE AIR VALVE ASSEMBLY IS ON THE
OPPOSITE SIDE OF THE PUMP.
Typical Installation