User's Manual
ALXC2X DATASHEET
Alinket Proprietary & Confidential Information
E-mail: sales@alinket.com Website: http://www.alinket.com
15
4. Specification
4.1 General Specification
The absolute maximum rating are shown in the following table:
Table 3 Range of Operation – General Specification
Symbol
Description
Min
Max
Unit
Tg
General Operating temperature
-30
85
°C
To
Operating temperature
-40
85
°C
Ts
Storage temperature
-40
85
°C
VDDIO
IO Power supply
0
3.6
V
VDDBAT
Power supply
0
3.6
V
RFi
RF input power
0
dBm
MSL
Moisture Sensitivity Level
3
RoHS
Restriction of Hazardous Substances
Compliant
4.2 Voltages
Table 4 Range of Operation-temperature
Supply Power
Max +3.6 Volt
Non-Operating Temperature
- 30° to 85° Celsius
Voltage ripple
+/- 2%
Max. Values not exceeding operating
voltage
Power supply for the ALXC2X Controller will be provided by the host via the power pins.
Table 5 Range of Operation - Voltages
Symbol
Min.
Typ.
Max.
Unit
VDD
3.0
3.3
3.6
V
4.3 Temperature and humidity
Table 6 Temperature and Humidity
Operating Temperature
-20° to 70° Celsius
Humidity range
Max 95%, No condensing, relative humidity
The maximum operating ambient temperature can be up to 85° Celsius, but exposure to absolute-
maximum-rated conditions may cause performance degradation and affect device reliability.