User Manual

Alinket Technology Co. (Shanghai) Ltd. Module Product User Manual
AN-ALX8XX-WIP2.2
22
Pin28 is used to implement the
restore-to-factory-default function, when the button was
pressed, the device will reboot, if the button was pressed
more than 5 seconds, the device will restore the factory
default settings. High level in normal operation and low level
to trigger the button.
Pin27 is connected to the AP indicator LED (output low
level signal while connected, and high level while
disconnected)
Pin24 is connected to the server indicator LED (output low
level signal while connected, and high level while
disconnected)
3.4 Electrical Characteristics
3.4.1 Extreme Limitations
Power Supply Max +3.6 Volt
Non-work
Temperature
-40 to 85 Celsius
Voltage Drifting +/-2% Not exceeding maximal working