8.3.19 Menu 19 Battery Type Setting
Select the correct battery type from Ni-MH battery pack, Li-ion battery pack and
Alkaline (and Oxyride) dry cells in order to display the battery-level icon correctly
and to perform the battery-charge using the DC-jack.
1. BAT-NI is displayed on the LCD.
2. Rotate the dial to select battery type from Ni-MH battery pack (BAT-NI), Li-ion
battery pack (BAT-LI) and Alkaline dry cells (BAT-AL).
• Cut out the Set Mode Function List below for use as a quick reference.
1. BS-ON Battery Save
2. TIMER Timer/Busy scan setting
3. BEP-ON Beep sound
4. 1750 Tone-Burst Frequency setting
5. SFT-OF CPU Clock Frequency shift
6. BCL-OF Busy Channle Lock Out
7. T-OFF TOT (Time-Out-Timer)
8. TP-OFF TOT Penalty
9. STP-5 Tuning Step
10. SFD-OF Shift Direction
11. 0.600 (7.600) Offset Frequency
12. TN-OFF Tone Squelch
13. 88.5 Tone Frequency
14. DCS-OF DCS
15. APO-OF APO (Auto-Power-Off)
16. SKP-OF Skip Channel
17. ATT-OF ATT (Attenuator)
18. CHG-ON Battery Charge
19. BAT-NI Battery type
Reference (Set mode)
NOTE:
Please set this parameter correctly. When the BAT-LI or BAT-AL is selected,
previously explained battery charge function can't be performed.
BAT-NI
(Ni-MH)
BAT-LI
(Li-ion)
BAT-AL
(Dry cell)