User's Manual
22
6
Press and hold
1.
key until activating the function menu.Rotate
the dial or use [UP/DOWN] keys to select
the menu 26 NAME C and press the dial
so that the last digit starts ashing. Up to 7
characters can be registered in each memory channel.
MENU 26: EDITING MEMORY NAME
Parameter Setting Mode (SET MODE)
The time-out timer limits the amount of continuously transmitting time.
When the transmitting reaches the selected TOT value, the transmission
will be automatically cut off and emits warning beep.
Press and hold
1.
key until activating the function menu.Rotate
the dial or use [UP/DOWN] keys to select the menu 27 TOT and
press the dial.
Rotate the dial or use
2.
[UP/DOWN] keys to
select the value:
1-30 Minutes, total of 30 setting
parameters.
OFF: TOT is turn off.
Press [
3.
PTT] to set and exit or press the dial to set and continue.
MENU 27: TIME-OUT TIMER(TOT)
Press and hold
1.
key until activating
the function menu.Rotate the dial or use
[UP/DOWN] keys to select themenu
No.28-31 menu The LCD displays "PG
PA", "PG PB", "PG PC", "PG PD". and
press the dial.
MENU 28-31: MICROPHONE PA,PB, PC,PD KEY SETUP
4-5 minutes is common and recommended.
N
OTE
Press and hold
1.
key until activating the function menu.Rotate the
dial or use [UP/DOWN] keys to select the
menu 25 MUTE and press the dial.
Rotate the dial or use
2.
[UP/DOWN] keys to
select the value:
TX: When the Main band is transmitting,
the sub band receive is mute.
RX: When the Main band is receiving, the
sub band receive is mute.
RX/TX: Suspends the sub band receive at
any time.
Press [
3.
PTT] to set and exit or press the dial to set and continue.
MENU 25: SUB BAND MUTE
REV and press the dial.
Rotate the dial or use
2.
[UP/DOWN] keys to select the value:
ON: Talk Around is turn on. The TX and
RX frequency will be reversed, along with
the CTCSS/DCS encode and decode
frequencies if used.
OFF: Turn off Talk Around
Press [
3.
PTT] to set and exit or press the dial to set and continue.
Turn the dial to select desired first
2.
character.Press the dial again to edit the
next. Press
key to store values and
exit the setting menu.
Press PTT to set and exit or press the dial to set and continue.
3.