User's Manual Part 2
47
Special Functions
Cable Clone
This feature will copy the programmed data and parameters in the master unit to slave units.
3.5 ΓΈ stereo-mini plug
Master side Slave side
Connection
Make a cable using 3.5 mm stereo-mini plugs as shown above. Make a master unit by setting and
programming it as desired. Turn off both units. Connect the cable between the DATA jacks on both
master and slave. Turn both radios on after the connection is made.
Plug configuration (both for Master/Slave)
GND
DATA
TX/RX
IMPORTANT: Be sure to connect cables while the unit is turned OFF.
Setting on the Slave side
1. Go to receive mode (VFO or Memory). Avoid
using 9600 bps data reception.
2. When it receives the clone data, LD*** shows
up on the display.
3. When the transmission is successfully finished,
the display will show [PASS].
4. Turn off the power. Disconnect the cable and
repeat the sequence to clone the next slave unit.