10. Maintenance / Reference
Reset
Resetting the transceiver returns all programmed contents to their factory default setting.
If any problems persist, resetting may overcome them and return the transceiver to normal opera-
tion.
Reset Procedure
While holding the FUNC key down, turn the power on.
All segments of the LCD will be displayed, then default set-
tings are displayed.
Factory Default Settings
Note: Take special care when resetting because all settings are initialized.
DR-135TMK
VFO frequency 145.00 MHz
CALL frequency 145.00 MHz
Memory channel 0-99
-
Offset direction -
Offset frequency 600 kHz
Channel step 5 kHz
Tone setting -
Tone frequency 88.5 Hz
DCS setting -
DCS code 023
Output power HI
Keylock setting OFF
TOT OFF
APO OFF
Squelch level 0
All LCD segments