HDD Error: Writing HDD error or unformatted HDD.
Network Disconnected: Disconnected network cable.
IP Conicted: Duplicated IP address.
Illegal Login: Incorrect user ID or password.
Record/Capture Exception: No space exists for saving recorded les.
Hot Spare Exception: Disconnected with the working device.
Responses to exception alarms include:
Audible Warning: Trigger an audible beep when an alarm is detected.
Send Email: Send an email with alarm information to a user or users when an alarm is detected.
Trigger Alarm Output: Trigger an alarm output when exception is detected.
To congure exception alarms:
1. Open the Exception menu. Go to Menu | Conguration | Exceptions
2. On the Exception Type line, open the drop down list and select the exception condition you want to congure. If you select
All, all exception conditions will be treated the way you congure the response.
3. Select the response options you want to use.
4. Click Apply to save your settings.
5. Repeat these steps for other Exception Types you want to congure.
2.11 Setting sensor alarms
Use this subsection to congure how the NVR reacts to sensor alarms wired to the RS-485 ALARM IN/OUT terminals on the back
panel. Alarm inputs can be normally open (N.O.), or normally closed (N.C.).