User guide
AuxBox Hardware Information
Client Call Recorder Installation and User Guide 41
M2250 Console Setup The M2250 Attendant Console connects to the phone system via a pair of
TN links. As a result, two Algo 4102 Digital AuxBoxes are required to
capture both call audio and Caller ID information from a M2250 console.
(If Caller ID is not required, then only one AuxBox is necessary). Special
configuration of the serial numbers on these two AuxBoxes is required for
Client Call Recorder to recognize the dual recorder. Please consult the Algo
Application Note 0304 (http://www.algosolutions.com/pdf/AN-0304.pdf)
for wiring details.
To configure the 4102 Digital AuxBox serial numbers:
1. Ensure both AuxBoxes are connected to the PC
2. Make note of each AuxBox serial number and to which channel you
have it connected: TN1 (data/audio channel) or TN2 (the LCD/Caller
ID channel). The serial number is listed on a label on the bottom of
each AuxBox.
3. Choose Tools>Hardware Maintenance
4. Select Yes to temporarily shut down recording
5. Select the AuxBox connected to the TN1 channel (the “Primary Aux-
Box”) and click Program Serial Number
6. Enter the serial number you noted earlier and add the suffix “M2250A”
to it. For example:
7. Press OK to return to the Hardware Maintenance window.
8. Select the AuxBox connected to the TN2 channel (the “Secondary Aux-
Box”)
9. Program the Secondary Auxbox to the same serial number as the Pri-
mary AuxBox but, instead of having “M2250A” at the end, type in
“M2250B”.
10. Press OK, then Exit to close the Hardware Maintenance window.