URS-1XE SERVICE AND PARTS MANUAL File name: URS-1XE Service Manual.
TROUBLESHOOTING AND SERVICE GUIDE The following is intended as a brief service guide, designed to diagnose most common problems. It is intended to be used only as a guideline. Should the unit require replacement of components, those components must be replaced by a trained and licensed refrigeration professional. While the unit is within the factory warranty period, all repairs require factory authorization before the work is performed.
NOISY OPERATION: AMBIENT TEMPERATURE: Is the ambient temperature about 90°F or above? The unit will need to run more at these elevated temperatures, therefore you will become more aware of sound generated by the compressor and the fans. REQUIRED RUN TIME: Is the unit running continuously for long periods of time? As the ambient temperature rises, the refrigerator requires more cooling, therefore sound from the compressor and fans will become more noticeable.
URS-1XE SERVICE PARTS LIST: The following is a list of all components and or hardware that are serviceable on the URS-1XE refrigerator unit. Please refer to the picture and associated text for reference and identification.
URS-1XE SERVICE PARTS LIST CONTINUED: Light Switch 210-0308 Filter Drier 220-0029 Refrigeration Controller 210-0425 Compressor 260-0108 Adjustable Foot 290-0351 Adjustable Foot 290-0175 SELECT SQUARE OR ROUND FOOT Wheel 290-0129 Compressor Protector Cover 260-0087 Lamp holder 210-0321 Pry-out Plug 510-0226 Plug Cap 290-0082 Refrigerator Bulb 210-0327 5
URS-1XE SERVICE PARTS LIST Strain Relief 210-0422 Arrow Clip 200-0043 Used to secure power cord Used to plug unused hinge mount holes Hinge (body side) 130-1684 Cable Tie (push mount) 210-0258 Hinge (door side) 130-1685 Bushing (shown) 130-1340 Wire Rack 230-0030 Condenser Coil 250-0072 Evaporator Coil 250-0071 6
URS-1XE SERVICE PARTS LIST CONTINUED: Shelf Clip 290-0140 Keyhole Support 290-0141 Pop Rivet 200-0106 Pilaster 290-0187 Shelf support pilasters and clips (brackets). Each unit contains 4 pilasters and 8 clips.
URS-1XE SERVICE PARTS LIST CONTINUED: Gasket also available as Separate part. See Pg.
URS-1XE SERVICE PARTS LIST CONTINUED: Magnetic Door Gasket part no.
Rear Wiring Harness 210-0435 Controller Wiring Harness 210-0436 10
URS-1XE SERVICE DATA: ELECTRICAL: VOLTAGE: 115 VAC FREQ: 60 Hz PHASE: 1 AMPS: 2.57 RLA: 1.3 LRA: 7.1 MCA: 2.9 REFRIGERATION: REFRIGERANT 134A (9OZ) SUCTION PRESSURE @ TEMP. ACCEPTABLE RANGE: 12 - 21 PS I (COIL TEMP. 10°F - 24°F) 18 PSI @ 20°F LIQUID PRESSURE @ TEMP. 125 PSI @ 100°F 170 PSI @ 120°F ACCEPTABLE RANGE: 125 - 147 PSI (AMBIENT TEMP. 80°F - 90°F) ACCEPTABLE RANGE: 170 - 197 PSI (AMBIENT TEMP.