Owner's Manual
8 
BRIQUETTE TRAY INSTALLATION: 
GAS CONNECTION—LIQUID PROPANE (LP)
NEVER CONNECT THE GRILL TO AN UNREGULATED GAS SUPPLY. 
Before proceeding, ensure the unit is fitted for LP gas. Connecting to an improper gas type will result in 
poor performance and increased risk of damage or injury. Total gas consumption (per hour) with all 
burners set on “HI” is a follows: 
 30” Grill       71,000 BTU 
 42” Grill      101,500 BTU 
 56” Grill w/ side burners  136,500 BTU 
 Dual Side Burners     35,000 BTU 
Installation of this cooking appliance must be made in accordace with local codes. In the absence of 
local codes, this unit should be installed in accordance with the National Fuel Gas Code No. Z223.1/ 
NFPA 54, Natural Gas and Propane Installation code CSA B149-1 , or Propane Storage and Handling 
Code B149.2. 
Manifold pressure with LP    Operating:  10.0” W.C.    Non-operating:  11.2” W.C. 
L.P. TANK REQUIREMENTS: 
Use only a standard 20 Lb. (5 Gal.) propane gas cylinder (18-1/4” H x 12-1/4” Ø). The tank must be in-
stalled in the upright position. Do not use a dented or rusty LP tank as it may be hazardous and should 
be checked by your LP supplier. Never use a cylinder with a damaged valve. 
Remove top grill. 
Briquette tray located over the 
gas burners 