Owners Manual
10 
GAS CONNECTION - NATURAL GAS (NG)
NEVER CONNECT THE GRILL TO AN UNREGULATED GAS SUPPLY. 
Before proceeding, ensure the unit is fitted for natural gas. Connecting to an improper gas type will result 
in poor performance and increased risk of damage or injury. The installation of this appliance must con-
form with local codes  or,  in the  absence of local codes, to the national  fuel gas  code, ANSI  Z223.1a-
1988. Installation in Canada must be in accordance with the Standard CAN/ CGA-B149.1 Natural Gas 
Installation or CAN/CGA-B149.2, Propane Installation Code. 
Manifold pressure with NG:  Operating:    4.0” W.C. 
          Non-operating:  4.5” W.C. 
          Optimum pressure: 7.0” W.C. 
NOTE:  To ensure proper heating performance of this appliance, verify that the gas line supply pressure 
  is adequate (7.0” W.C. supply pressure is preferred) to maintain 4.5” W.C. manifold pressure. 
  Use a minimum 1/2” ID flex hose to prevent gas starvation. 
NATURAL GAS CONNECTION: 
Ensure that the service pipe supplying the Grill is fitted with a shut 
off valve conveniently positioned  and easily accessible as  an 
emergency gas shutoff. 
Your  ALFRESCO™  Gourmet  Grill  for  use  with  Natural  Gas 
comes  equipped  with  it  own  regulator  which  MUST  NOT  be  re-
moved.  If  this  regulator  needs  to  be  replaced  use  only  the  type 
specified by ALFRESCO™ Gourmet Grill for this appliance. 
CAUTION 
CYLINDERS MUST BE STORED OUTDOORS IN A WELL-VENTILATED AREA OUT OF THE 
REACH OF CHILDREN. 
DISCONNECTED LP CYLINDERS MUST HAVE THREADED VALVE PLUGS TIGHTLY INSTALLED, AND MUST NOT 
BE STORED IN A BUILDING, GARAGE OR ANY OTHER ENCLOSED AREA. THE GAS MUST BE TURNED OFF AT 
THE SUPPLY CYLINDER WHEN THE UNIT IS NOT IN USE. IF THE APPLIANCE IS STORED INDOORS, THE CYL-
INDER MUST BE DISCONNECTED AND REMOVED FROM THE APPLIANCE.  
WARNING
ENSURE THAT THE GAS 
SUPPLY HOSE DOES 
NOT COME IN CONTACT 
WITH THE GRILL BODY
LP GAS CONNECTION TO LP PIPED SYSTEMS: 
An LP piped system is one with a large central LP tank that feeds the entire household. Those systems 
are normally equipped with a high pressure regulator by the large LP tank and low pressure regulators 
close to the home. 
WARNING 
YOUR ALFRESCO™ GOURMET GRILL’S PRESSURE 
REGULATOR  HAS  A  MAXIMUM  INPUT  PRESSURE 
OF  14”  WC. (OR APPROX. .5 PSI) , AND A SAFETY 
LIMIT OF 69” WC. (2.5 PSI).  
REGULATOR NOTICE
Exposure to pressures above the safety limit 
of 69” WC. will permanently damage the gas 
regulator  requiring  a  replacement.  OVER 
PRESSURE  DAMAGE  IS  NOT  COVERED  BY 
YOUR ALFRESCO WARRANTY  