Gas Conversion
Page 5 
Barbeques cont. 
8– If your unit is equipped with a Sear-Zone™ burner, the valve has an orifice mounted externally to the 
 valve body. The orifice is directly attached to the barbeque fire box with a bracket and connected to 
 the valve with a flexible stainless tube. (Figure 7) 
 It is mounted on this bracket along with the Sear-Zone™ igniter electrode. Remove and replace this 
 orifice from the inside of the firebox. (Figure 8) 
(Figure 7) 
(Figure 8) 
FLEXIBLE 
PIPING 
MOUNTING 
BRACKET 
SEAR-ZONE™ 
ORIFICE 
VALVE BODY  ELECTRODE 
(Figure 9) 
9– The smoker unit’s orifice is also mounted externally from the control valve body. It is connected with a 
 small 3/16” Ø aluminum tube. The orifice is mounted on a bracket attached to the fire box. 
 To replace this orifice, remove the mounting bracket from the fire box and gently bend the aluminum 
 tubing outward to prevent kinks. After replacement, re-install bracket / orifice assembly back into the 
 fire box. (Figure 9) 
SMOKER ORIFICE 
BRACKET 
3/16ӯ ALUMINUM TUBING 
FIRE BOX 