BRIQUETTE TRAY INSTALLATION: 
GAS CONNECTIONS: 
NEVER CONNECT THE GRILL TO AN UNREGULATED GAS SUPPLY. 
Total  gas  consumption  (BTUH)  with  all 
burners set on “HI” is a follows: 
LIQUID PROPANE (LP): 
Before proceeding, ensure the unit is fitted for LP gas. Connecting to an improper gas type will result in 
poor performance and increased risk of damage or injury. 
Installation of this  cooking  appliance  must  be made  in  accordace  with  local  codes. In the  absence  of 
local codes,  this  unit should  be  installed in accordance  with the National Fuel Gas Code No. Z223.1/ 
NFPA 54,  Natural Gas and Propane Installation code CSA B149-1 , or Propane Storage and Handling 
Code B149.2. 
Manifold pressure with LP    Operating:  10.0” W.C.    Non-operating:  11.2” W.C. 
L.P. TANK REQUIREMENTS: 
Use only a standard 20 Lb. (5 Gal.) propane gas cylinder (18-1/4” H x 12-1/4” Ø). The tank must be in-
stalled in the upright position. Do not use a dented or rusty LP tank as it may be hazardous and should 
be checked by your LP supplier. Never use a cylinder with a damaged valve. 
The LP gas cylinder must be constructed and marked in accordance with the specifications for LP gas 
cylinders of the U.S. Department of Transportation (DOT). The cylinder must be provided with a shut off 
valve terminating in an LP gas supply cylinder valve outlet specified, as applicable, for connection type 
QCC1 in the standard for compressed gas cylinder valve outlet and inlet connections ANSI/CGA-V-I. 
Remove top grills. 
Briquette trays located over the 
gas burners 
MODEL:  LP GAS  NG GAS 
ALXE-30SZ  63,100  64,200 
ALXE-36SZ  82,000  85,800 
ALXE-42SZ  84,200  88,200 
ALXE-56SZ  122,000  124,000 
ALXE-56BFG  116,900  122,900 