Gas Conversion

Page 5
Barbeques cont.
8– If your unit is equipped with a Sear-Zone™ burner, the valve has an orifice mounted externally to the
valve body. The orifice is directly attached to the barbeque fire box with a bracket and connected to
the valve with a flexible stainless tube. (Figure 7)
It is mounted on this bracket along with the Sear-Zone™ igniter electrode. Remove and replace this
orifice from the inside of the firebox. (Figure 8)
(Figure 7)
(Figure 8)
FLEXIBLE
PIPING
MOUNTING
BRACKET
SEAR-ZONE™
ORIFICE
VALVE BODY ELECTRODE
(Figure 9)
9– The smoker unit’s orifice is also mounted externally from the control valve body. It is connected with a
small 3/16” Ø aluminum tube. The orifice is mounted on a bracket attached to the fire box.
To replace this orifice, remove the mounting bracket from the fire box and gently bend the aluminum
tubing outward to prevent kinks. After replacement, re-install bracket / orifice assembly back into the
fire box. (Figure 9)
SMOKER ORIFICE
BRACKET
3/16ӯ ALUMINUM TUBING
FIRE BOX