Use and Care Manual

OPERATION
INSTRUCTIONS
Perform
all leak tests outdoors.
Extinguish
all open flames.
NEVER
leak test when smoking.
Do
not use the fire
pit
until all
connections
have been
leak
tested
and
do
not
leak.
Leak
Test
Hose
/
Regulator
connection
Regulator / Cylinder
connection
1. Make 2-3o2.
of
leaktestsolution
(one part
liquid dishwashing
detergent and three
partswater).
2. Apply
several drops of solution where hose attaches
to
regulator.
3. Apply several
drops of solution where regulator
connects to cylinder.
4. Make sure all fire
pit
and
light valves
are OFF.
5. Turn cylinder valve
ON.
lf bubbles
appear at any connection
,
there is a leak
.
1. Turn
cylinder
valve
OFF.
2. lf leak
is at hose/regulator connection:
tighten connection and
perform
another
leak test. lf bubbles
continue appearing,
the hose
should
be returned to the
place
of
purchase.
3,
lf
leak is at regulator/cylinder valve connection:
disconnect, reconnect,
and
perform
another leak
test. lf
you
continue
to
see bubbles after several
attempts, cylinder valve is
defective and should be
returned to cylinder
place
of
purchase.
lf NO bubbles appear
at any
connection
,
the connectiors are secure
NOTE:Whenever
gas
connections
are loosened or removed
yog
must
perform
a
complete
leak test
Complete installation.
.t2