SDS
Page 3 of 6
Date:11.Jul.2015 No.:JST20150711012S
We
ight Percent (%)
Components Name CAS No.
Light
Purple
Deep
Blue
Grass
Green
Lake
Blue
Yellow Light
Orange
Khaki
Brown
Water(Aqua) 7732-18-5 74.55 72.35 71.85 74.55 72.85 73.35 73.25 71.85
Potassium sorbate 590-00-1 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15
Glycerol 56-81-5 25 25 25 25 25 25 25 25
Basic Violet 11 2390-63-8 0.3 2 0.5 0.1
Acid Black 1 1064-48-8 0.5 0.3 1
Acid Yellow 11 6359-82-6 1.5 2 0.83
Basic Green 1 633-03-4 1 0.2
Sunset Yellow FCF 2783-94-0 1.5 2
Acid Red 1 3734-67-6 0.47
4
First aid measures
.After inhalation: Remove from exposure and move to fresh air immediately. If not breathing, give artificial respiration.
If breathing
is difficult, give oxygen. Get medical aid.
.After skin contact: Normally does not need first aid after skin contact,When need flush skin with plenty of water for a few
minutes . Get medical aid
If irritation or sensitization develops or persists.
.After eye contact: Immediately flush eyes with plenty of water for at few minutes, occasionally lifting the upper and
lower eyelids.
.After swallowing: If victim is conscious and alert, give 2-4 cupfuls of milk or water. Never give anything by mouth to an
U
nconscious person. Get medical aid.
5 Fire-fighting measures
.General Information: As in any fire, wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH
(approved or equivalent), and full protective gear. Decomposes at high temperatures, resulting in toxic and corrosive products.
Containers may explode when heated.
.Extinguishing Media: CO2, Dry Chemicals, Foam-Fog
.Flash point: Not available
.
Special fire & explosion hazards: Fire may Decomposition harmful smoke and gas, Negligible explosion hazard.
6 Accidental release measures
.Small Spill and Leak: Mix absorb leaked material with (sand, diatomite, sawdust) then Cleaning and placed
into a suitable container handling.
.Large Spill and Leak: Isolation accident area to prevent the leak products to be contaminated , Dug Pit to gather leaked
liquidand then to recycling collection the leak products.
Ningbo Jeston Certification Services Co.,Ltd. TEL:+86 574 8737 7879 FAX: +86 574 8777 9860
宁波市朝晖路 416 弄 262 号商务楼 1105 邮编:315040 E-mail:jeston@nbjeston.com www.nbjeston.com