PORTABLE AIR CONDITIONER OWNER'S MANUAL Models MPF-12CR Thank you for purchasing this product. Please read this Owner's Manual carefully before operating. Table of Contents.................................. ......................
CONTENTS 1.SAFETY RULES............................................................................. 1 2.NAMES OF PARTS.......................................................................... 2 3.ACCESSORIES................................................................................ 2 4.OPERATION PANEL OF THE AIR CONDITIONER........................ 3 5.OPERATING INSTRUCTION FOR THE AIR CONDITIONER ........ 4 6.INSTALLATION...............................................................................
SAFETY RULES 1. DO NOT CONNECT UNIT TO ANY AC SOCKET IN DISREPAIR OR WITH CONNECTIONS. 2. DO NOT USE IN THE FOLLOWING LOCATIONS: - NEXT TO SOURCE OF FIRE. - AN AREA WHERE OIL IS LIKELY TO SPLASH. - AN AREA EXPOSED TO DIRECT SUNLIGHT. - AN AREA WHERE WATER IS LIKELY TO SPLASH. - NEAR A BATH, ASHOWER OR A SWIMMING POOL - IN THE GREEN HOUSE 3. NEVER INSERT YOUR FINGERS OR ANY FOREIGN OBJECTS INTO THE AIR OUTLET. TAKE SPECIAL CARE TO WARN CHILDREN OF THESE DANGERS. 4.
NAMES OF PARTS OPRATION PANEL REAR COVER AIR INLET FRONT COVER AIR OUTLET AIR OUTLET OUTDOOR WATER PUMP DRAIN HOSE AIR INLET OUTDOOR REMOTE CONTROLLER CASTER INDOOR CONTINUOUS DRAIN HOSE POWER CORD SIDE VIEW FRONT VIEW AIR INLET OUTDOOR REAR VIEW Fig.
OPERATION PANEL OF THE AIR CONDITIONER(COOLING AND HEATING) DIGITAL DISPLAY FAN SPEED INDICATOR COOL/DRY/FAN/HEAT INDICATIOR Green lamp will light when the mode is selected WATER FULL INDICATOR Red lamp will blink when the tank is full TEMP SETTING BUTTON Press your desired room temperature setting by pressing the button (up) or button (down) POWER INDICATOR INFRARED SIGNAL RECEIVER POWER BUTTON Turn on/off the unit MODES BUTTON Select the operation mode from COOL.DRY.FAN.
OPERATING INSTRUCTING FOR THE AIR CONDITIONER Before Starting This Unit 1) Select a suitable location, make sure you have easy access to an electrical outlet. 2) Install the Flexible Exhaust Hose and the Adjustable Window Slider Kit as depicted in Fig.5 & Fig.5a Fig.5a Fig.5 NOTE: Step 2 is required only while using the cooling mode 3) Plug the unit into a 115V~60Hz grounded electrical outlet. 4) Make sure the water pump drain hose is correctly installed.
O O O O 2 COOLING OPERATION (Operating temperature range: 17 C-32 C/63 F-90 F) - Press the "MODE" button several times until the "COOL" indicator light comes on. - Press the "TEMP SETTING" buttons " " or " " to select your desired room temperature. (17OC-30OC/63OF-86OF) - Press the "FAN SPEED" button to choose the fan speed. O O O O 3 DEHUMIDIFYING OPERATION (Operating temperature range: 13 C-32 C/55 F-90 F) - Press the "MODE" button several times until the "DRY" indicator light comes on.
INSTALLATION 1 IMPORTANT: Install the mobile air conditioner in a flat and spacious location where the air outlets will not be covered up. A minimum clearance of 11.8in from a wall or other obstacles should be kept. The appliance shall not be used in the laundry. The plug shall accessible after appliance is positioned. Wiring shall be done according to National rules. 11 .8 1 in . 11 81 in Fig.7 2 DUCT MOUNT INSTRUCTIONS: Exhaust Air Oulet Duck Fig.8 A) TEMPORARY1.
Window Kit Installation Your window kit has been designed to fit most standard Vertical and horizontal window applications, However, it may be necessary for you to improvise/modify some aspects of the installation procedures for certain types of window. Please refer to Fig. 11 & Fig. 11a for minimum and maximum window openings.
TROUBLE SHOOTING TROUBLES POSSIBLE CAUSES SUGGEST REMEDIES 1. UNIT DOES NOT - Water full indicator blinks, water tank Dump the water in the water tank. START WHEN is full. PRESSING 1/0 BUTTON - Room temperature is higher than Reset the temperature. the set temperature.(Heating mode) - Room temperature is lower than Reset the temperature. the set temperature.(Cooling mode) 2. NOT COOL ENOUGH - The windows or doors in the room are not closed.
, OWNER S MANUAL REMOTE CONTROLLER FOR PORTABLE AIR CONDITIONER SET TEMPERATURE( C /F ) AUTO COOL DRY HEAT FAN HIGH MED LOW TEMP MODE ON/OFF FAN SPEED TIMER ON TIMER OFF RESET LOCK 9
CONTENTS 1.Warning------------------------------------------------------------------------------------------------ 10 2.Remote Controller Specifications------------------------------------------------------------ 11 3.Performance Features--------------------------------------------------------------------------- 11 4.Introduction of Function Buttons on the Remote Controller----------------------- 11 5.Names and Functions of indicators on Remote Controller-------------------------- 12 6.
Remote Controller Specifications Model R51H, R51H/C Rated Voltage 3.0V Lowest Voltage of CPU Emitting Signal 2.0V Reaching Distance Signal Range 8m Environment -5 C 60 C(-41OF~140OF) ~ Performance Feature 1. Operating Mode: COOL HEAT DRY FAN and AUTO. 2. Timer Setting Function in 24 hours. 3. Indoor Setting Temperature Range : 17 C~30 C.(63OF ~86OF) 4. LCD (Liquid Crystal Display) of all functions. 5.
Names and Functions of indicators on Remote Controller 1 2 3 4 TRANSMISSION Indicator: This indicator lights when remote controller transmits signals to indoor unit. 1 2 MODE Display: Shows the current operation modes-- AUTO, COOL, DRY , HEAT and FAN. HEAT only available for heat pump model. HEAT PUMP ONLY - LOCK display is displayed by pushing the LOCK button. Push the LOCK button again to clear display. TIMER Display: This display area shows the settings of TIMER.
COOL , HEAT, and FAN ONLY Operation 1. If the AUTO mode is not comfortable , you may manually override the settings by using COOL, DRY, HEAT(HEAT PUMP units only), or FAN ONLY modes. 2. Push the TEMP button to set the desired room temperature. When in COOLING mode, the most comfortable settings are 21 C/70OF or above. When in HEATING mode, the most comfortable settings are 28oC/82OF or below. 3. Push the FAN SPEED to select the FAN mode of AUTO, HIGH, MED or LOW. 4. Push the ON/OFF button.