Instructions / Assembly
`
24
NOTE: The Obstruction Sensitivity /Stall Force is adjustable in 9 levels.
REV 12a
How to Operate
The user may operate the opener once all adjustment setting is finished.
With the gate in its closed position, press and release the remote control, the gate will move to the
programmed opening position and stop.
With the gate in its opened position, press and release the remote control, the gate will move to the
programmed closing position and stop.
While the gate is moving, press and release the remote control, the gate will stop moving immediately.
The next command from the remote will reverse the gate direction and the gate will stop at its
programmed opening/closing position.
The gate will stop in case of obstruction during opening. The command from the remote control will
reverse the gate direction and the gate will stop at its programmed closing position.
The gate will reverse in case of obstruction or stall force during closing, and it will move to the
programmed opening position.
Emergency Release
Installation for Push-to-Open Gates
Ensure the gate does not open into public areas.
In case of the system failure or power cut-off, the gate can be
manually opened.
Insert the triangular key inside the triangular plug located on the
bottom of actuator body, and then turn clockwise (left actuator) or
counter-clockwise (right actuator) till the stop. Motors shall be
released. The inverse operation restores the gate automation.
In a Push-to-Open installation, gate opens out from the
property. A Push-To-Open Bracket (PSO part) is required to
be used for each gate. The gate is in the closed position
during the opener is installed.
Step 1
Place the PSO bracket between the two post brackets.
Insert the M10x30 bolt through the center hole of the post
bracket and PSO bracket as shown. Place a ¢ 10
washer , ¢10 lock washer and M10 nut on the bottom of
the bolt and hand tighten.