Instructions / Assembly
`
18
REV 12b
Actuator 1
Insert the stripped cable wires into the appropriate terminals on the opener terminals block. The red
wire should be inserted into the “MOTOR1+” terminal, the black wire into “MOTOR1-“, the blue wire
into ULT1, the green wire into COM, and the yellow wire into DLT1 terminal.
Actuator 2
Similar as the connection of Actuator 1, insert the stripped cable wires into the appropriate terminals on
the opener terminals block. The red wire should be inserted into the MOTOR2+ terminal, the black wire
into MOTOR2-, the blue wire into ULT2, the green wire into COM, and the yellow wire into DLT2
terminal.
NOTE: It is recommended that Gate Opener 1 is installed in the Master Gate, and Gate Opener 2 is
installed in the Slave Gate.
Alarm Lamp (optional)
The red wire of the alarm lamp should be inserted into either LAMP (#11) terminal, the white wire into the
other one (#12).
Back-up Battery (optional)
The “24V+” of the battery should be wired to the BAT+ (#13) terminal, “24V-” should be wired to “BAT-”
(#14) terminal.
Recommend strongly to use the controller LM118 (WA4004
)
to connect Battery with battery’s
Terminal of control board if the battery is used as the primary power supply in system (such as
SOL PLUS KIT). Please refer to the user manual of control LM118
(
WA4004
)
separately.
Photocell Beam System (PBS) (optional)
Use a 2-core cable to connect the “- ~” terminal of the photocell’s emitter to the “14” terminal, the “+ ~”
terminal to the “9” terminal. Also the “- ~” and “+ ~” terminals of the photocell’s receiver should be
connected to the “16” and “17” terminals in parallel.
Use another 2-core cable to connect the “COM” terminal of the receiver to the “17” terminal, the “NC”
terminal to the “18” terminal.
Push Button (optional)
The red wire should be inserted into either O/S/C terminal, the white wire into the other one.
Loop Detector (optional)
First insert the LOOP DETECTOR BOARD into the CONTROL BOARD, and then connect the
twisted-pair to the “LOOP” terminal.
Electric Lock (optional)
The electric lock should be wired to the “LOCK” terminal.
External Receiver (optional)
The BROWN wire of the external receiver should be connected into the “19” terminal.
The BLACK wire of the external receiver should be connected into the “20” terminal.
The RED wire of the external receiver should be connected into the “9” terminal.