` Table of Contents Safety Installation Information ………………………………………..…………………………………...... 2-3 Dual Gate Opener Parts List (AS1200) ……………………….…………………….……………..……….….4 Single Gate Opener Parts List (AS600) ……………………….…………………….……………..……….….5 Optional Accessories Parts List………...………….……………….…………...…………………..…….…….6 Technical Specifications & Features …………….…………………..…………………...……….…………....7 Installation Overview …………………………….…………………….…………………...……………….…8-9 Preparation for Installation……………………….…………………………..………………………..
` Safety Installation Information 1. READ and FOLLOW all instruction. 2. The gate opener is intended for use with Class I vehicular swing gates. Class I denotes a vehicular gate opener (or system) dwellings, or a garage or parking area associated therewith. Install the gate opener only when the opener is appropriate for the construction and the usage class of the gate. 3.
` 11. Controls intended to be used to reset an operator after 2 sequential activations of the entrapment protection device or devices must be located in the line of sight of the gate, or easily accessible controls shall have a security feature to prevent unauthorized use. Never allow anyone to hang on or ride the gate during the entire travel of the gate. 12. Each gate opener is provided with two safety warning placards.
` Dual Gate Opener Parts List(AS1200) Opener and Mounting Hardware 4 REV 12a
` Single Gate Opener Parts List(AS600) Opener and Mounting Hardware 5 REV 12a
` Optional Accessories Parts List Tools Needed: ·Power Drill ·Tape Measure ·Open End Wrenches — 14# &17# or Adjustable Wrenches ·Wire Strippers ·C-Clamps — small, medium, and large ·Level ·Hacksaw or Heavy Duty Bolt Cutters ·Phillips Screwdriver ·An extra person will be helpful 6 REV 13b
` Technical Specifications & Features Specifications: ·Input: 230V/50Hz or 120V/60Hz ·Motor voltage: 24VDC ·Power: 80W each actuator ·Current: 3A ·Actuator speed: 16mm/s ·Max. actuator travel: 385mm ·Max. Weight per a gate: 600lbs ·Max.
` 8
` REV 13b 9
` Preparation for Installation The proper position of the post brackets is a decisive factor to the efficiency and leverage of the gate opener. The distance (usually it is 2.5cm /1 inch or more) between the gate opener and the gate is also determined by the proper position of the post brackets. Both round and square post can be used because of the curved design of the post brackets. When mounting the post brackets, use bolts long enough to pass through the entire post.
` NOTE: Pay attention to the distance A when installing the opener. It MUST be longer than or at least equal to 8cm (3-1/4”). Otherwise, the opener force cannot be effective complete. The opener force is not notably related with the power of the opener. NOTE: We recommend you keeping the actuator housing with screw holes outward as Fig. A for opener installation so as to have a bigger opening angle.
` Step 1 Place the post pivot bracket between the two post brackets. Insert the M10 x 30 bolt through the center hole of the post bracket and post pivot bracket as shown. Place a ¢10 washer , ¢10 lock washer and M10 nut on the bottom of the bolt and hand tighten. Step 2 Attach the gate bracket and post bracket assembly to the opener by inserting a clevis pin. Secure the clevis pins using the hairpin clips.
` Step 4 Determine the optimum position of the pivot bracket on the post bracket assembly by ensuring a minimum 2.5cm (1 inch) distance exists between the gate and the gate opener in both the gate-open and gate-closed positions. To ensure the minimum 2.5cm (1 inch) distance maintained in the gate-closed position, remove the clevis pin from the gate bracket while holding the gate opener, and then close the gate. Move the gate opener so as the gate bracket and the opener are aligned.
` Installing the Mounting Hardware Step 5 Sign the bolt-hole point on the gate bracket and gate. Do this by placing a punch or a sign in the middle of each bolt slot on the post bracket assemblies and the gate bracket. It allows slight adjustments to the post bracket. Then remove the post bracket and gate bracket by taking off the C-clamps. Step 6 Using a drill and a bit of ¢10.5, drill holes through the post and the gate at the sign bolt hole point.
` Mounting the Control Box Step 1 To install the control box use the deck screws (not provided). Ensure the control box is installed in a secure surface and at least 100 cm (40 inches) above the ground to protect it from rain, snow, etc. which probably cause damage to the control box. Warning: Before connecting the AC power cable to the control box, check the plug of power cable is disconnected from AC power socket.
` Step 3 Insert the cable of the second gate opener and alarm lamp cables into the control box through middle strain relief. Then repeat step 2. Step 4 Insert other cables into the control box through rightmost strain relief. Then repeat step 2. NOTE: Only motor cables (1.5m length) are provided. Other cables are subject to site installation requirement and not provided. CAUTION: Make sure the cable outlet hole in the Control Box is always down during installation so as to drain off the water.
` Connecting of the control board 17 REV 12b
` Actuator 1 Insert the stripped cable wires into the appropriate terminals on the opener terminals block. The red wire should be inserted into the “MOTOR1+” terminal, the black wire into “MOTOR1-“, the blue wire into ULT1, the green wire into COM, and the yellow wire into DLT1 terminal. Actuator 2 Similar as the connection of Actuator 1, insert the stripped cable wires into the appropriate terminals on the opener terminals block.
` Wired Keypad (24VDC) (optional) The RED wire of the wired keypad should be connected into the “9” terminal. The BLACK wire of the wired keypad should be connected into the “14” terminal. The WHITE wire of the wired keypad should be connected into the “19” terminal. The BLUE wire of the wired keypad should be connected into the “20” terminal. Solar Panel (optional) Please refer to the manual instruction of solar panel and controller separted.
` Setting of the Control Board 1. Check again for completed and correct assembly of your swing gate opener and gate. Plug the Power Grounded Cord into the nearest AC outlet. The Digital Display on the Control Board will flash with “- -”. The unit is in standby. 2. Single/Dual Gate Set Press and hold the “FUNC” button for more than 4 seconds. The Digital Display will indicate “P1”. Gate opener is on the SINGLE/DUAL Gate setting.
` (Factory set is 3 seconds) Press the “FUNC” button to store the data when the close interval is set. The Digital Display will indicate “P5”. Now Close Interval Set is finished. 6. Adjust the Obstruction Sensitivity/Stall Force When the Digital Display indicates “P5”, the gate opener is on the Stall Force Adjustment. Without a properly installed safety reversal system, person (particularly small children) could be SERIOUSLY INJURED or KILLED by a closing gate.
` 7-b. Adjust the MRT of MOTOR2 When the Digital Display indicates “P8”, you can adjust the MRT of MOTOR2. Please perform the same procedure as adjusting MOTOR1 (7-a). Press the “FUNC” button to store the data when you finish setting. The Digital Display will indicate “P9”. Now MOTOR2 adjustment is finished. 8. Set the Safety Photocell Beam System (PBS) (Optional) When the Digital Display indicates “P9”, the gate opener enters PBS set mode.
` E.g. When the Soft Start Period (STP) is set at 3 sec, and the GRP is 23 sec, how can we get 4 sec of Soft Stop Period (SPP) to meet the requirement? The answer is clear, i.e. we may set the Fast Running Period (FRP) at 16 sec (23 – 3 – 4 =16 sec). 12. Return to Factory Set When the Digital Display indicates “Pd”, press and release the “INC” or “DEC” button. All data will return to factory set, the Digital Display indicates “dF”. 13. If all of data is set and no other change needed, press “FUNC” Button.
` How to Operate The user may operate the opener once all adjustment setting is finished. With the gate in its closed position, press and release the remote control, the gate will move to the programmed opening position and stop. With the gate in its opened position, press and release the remote control, the gate will move to the programmed closing position and stop. While the gate is moving, press and release the remote control, the gate will stop moving immediately.
` Step 2 Attach the gate bracket and post bracket assembly to the opener by inserting a clevis pin. Secure the clevis pins using the hairpin clips. Step 3 With the gate in closed position and with the opener in their retracted position, place the opener with the gate bracket and post bracket assembly on to the gate post and the gate. Position the gate bracket and the post bracket assembly so that the gate opener is level with the horizontal cross member of the gate.
` Maintenance Warning: Disconnect power before servicing. 1. Using a clean, dry cloth, wipe the gate opener shaft, and then apply a silicone spray to reduce its friction. In cold climates where temperatures reach 1°C (30°F) or less, spray silicone on the actuator every 4~6 weeks to prevent freeze up. 2. Regularly check gate hinges to make sure gate is swinging smoothly and freely. Grease hinges if needed. 3. Check your installation periodically, as hardware and posts will shift.
` • Check that wires to the limit switch are not shorted. • Ensure that the motor cable is away from sources of electrical interference, such as electric fences, power lines etc. 6. Gate opens, closes or stops on its own •Ensure that the key for manual release is in the lock position. Refer to page 24.
` Quick-Setting Guide 28 REV 12a
` 29 REV 12a
` 30 REV 12a
` 31
` 32
` www.WholesaleGateOpener.com 7106 S 220th St, Kent WA 98032 USA sales@WholesaleGateOpener.