Instructions / Assembly
AC2000 SLIDING GATE OPERATOR
z Pedestrian mode: This feature can be used to open gate about 0.3~1.5 meters for
people pass through.
z Safe guard (Infrared photocell): If infrared beam is broken during closing, the gate will
reverse and go open immediately. This feature will not function if the gate is in fully
opened and closed positions or during opening.
z Open priority: The gate will return to open if press ‘OPEN’ button of external button
switch during closing.
z Loop detector: If loop detector detects vehicles during closing, the gate will reopen
immediately and stay open until the vehicles move out of the loop. After vehicles move out
of the loop, the gate will stop and then close after 10 seconds.
If loop detector detects vehicles when the gate stops, the gate will open immediately. After
vehicles move out of the loop, the gate will stop and then close after 10 seconds.
8. Check
z Check the power supply, grounding and wiring before running the device.
z Release the clutch with the release key to determine whether or not the gate can be
moved manually. If everything is in good working order, tighten the clutch with the key.
z Switch the power on and run the device to ensure that the gate is sliding smoothly.
z Adjust the magnet position until the gate opened and closed properly at the limited
positions.
9. Maintenance
Every six months check the following items for proper operation of the unit.
z Loosen the oil screw on the motor to avoid leakage.
z Check the chain lubricant and add 2# grease regularly.
z Lubricate shafts and sprockets.
z Keep operator clean at all times.
z Check and tighten anchors bolts.
15