Instructions / Assembly

AC2000 SLIDING GATE OPERATOR
and replaced the original auto-close time of pedestrian mode that you have been set in Set
auto-close function of pedestrian mode section.
*Keep width of pedestrian mode, cancel auto-close function of pedestrian mode:
Please
turn on the first and the second DIP switch (See Fig.8 No.18) to ON position. Press button
4 to open the gate (see Verify open direction section). Wait some seconds (3~10 sec.),
then press the same button/button 4 to stop the gate. Wait until the gate close
automatically (45 sec.). Press the same button again to stop the gate or the gate will stop
automatically at its closed position if the magnetic limit switch is reached. After this setup is
complete, return DIP switch 1 to OFF position immediately. Thus the width of pedestrian
mode has been reserved, the auto-close function of pedestrian mode has been canceled.
Note: the new width of pedestrian mode has been re-programmed in the device and
replaced the original width.
If you open the gate with button 4, the gate will stop at the expected position that you have
set, but the gate will not close automatically.
z Turn on the second DIP switch to OFF position (Factory preset: OFF position), both auto
close function and auto-close function of pedestrian mode were shut off.
z Safe guard (Infrared device)
: If the infrared beam is broken during closing, the gate will
reverse and open immediately.
z Tuning the auto-reverse safety function
: rotate the ‘Force Adj. VR’ knob (See Fig.8 No.7)
with a screwdriver. The opening & closing force may be increased or decreased by
rotating clockwise or counterclockwise. NOTE: if the gate fails to reverse in the event of
obstruction, then the opening force or closing force should be checked for conformity with
requirements and adjusted accordingly. The gate will reverse if obstructed when closing,
and will stop if jammed when opening.
Please exchange wires ‘V’ and ‘W’ if the auto-reverse direction is wrong. Exchange wires
‘OP’ and ‘CL if the limit direction is wrong.
z WARNING: Do not attempt to tune the gate by placing your hand, arm or other body part
in the path of the gate, as serious injury could result. Damage to the gate operator motors
may also occur by placing a heavy immovable object in the path during the testing phase.
Instead, place a light object in the path (e.g., a chair or trash can) which can be pushed
out of the way without causing damage to gate motors, if the setting is still too high. Note:
This auto reverse function should be regularly inspected and adjusted if necessary. Once
the tuning is complete you may replace the cover.
Activities Covered in this section
z Remote control (Single-button mode): With each press of the button, the gate will open,
stop, close or stop cycle.
z Single-button switch/keypad (not supply): with each press of the button, the gate will
close, stop, open or stop cycle.
z Auto-reverse function: After adjusting the opening force and closing force, the gate will
reverse and go open if obstructed when closing, and will stop if jammed when opening.
z Auto-close function: This feature can be selected to make the gate stay open for several
seconds before it automatically closes. The auto-close time can be adjusted to between 0
and 44 seconds.
14