Instructions / Assembly

AC2000 SLIDING GATE OPERATOR
canceled.
z Pedestrian mode:
Pedestrian mode can be used to open gate about 0.3~1.5 meters for
people pass through.
*Set width of pedestrian mode:
Please turn on the first and the second DIP switch (See
Fig.8 No.18) to ON position. Press button 4 to open the gate (see Verify open direction
section), Wait until the gate travels the distance according to your requirements (the
distance range is 0.3m~1.5m or wait for 3~10 sec.), it is regarded as ‘the width of
pedestrian mode’. Then press the same button/button 4 to stop the gate, wait for some
seconds (1~ 44 sec.). Close the gate by pressing the same button/button 4. Press the
same button again to stop the gate or the gate will stop automatically at its closed position
if the magnetic limit switch is reached. After this setup is complete, return DIP switch 1 to
OFF position immediately. Thus the width of pedestrian mode has been set.
If you open the gate with button 4, the gate will stop at the expected position that you have
set.
*Set auto-close function of pedestrian mode:
Please turn on the first and the second DIP
switch (See Fig.8 No.18) to ON position. Press button 4 to open the gate (see Verify open
direction section), wait some seconds (3~10 sec.). Then press the same button/button 4
to stop the gate, wait some seconds according to your requirements (1~44 sec.), this
period of time is regarded as ‘auto-close time of pedestrian mode’. Close the gate by
pressing the same button/button 4. Press the same button again to stop the gate or the
gate will stop automatically at its closed position if the magnetic limit switch is reached.
After this setup is complete, return DIP switch 1 to OFF position immediately. Thus the
auto-close function of pedestrian mode has been set.
Note: the new width of pedestrian mode has been re-programmed in the device and
replaced the original width you have set in Set width of pedestrian mode section.
If you open the gate with button 4, the gate will stop at the new expected position that you
have set, after some seconds as what you have set, the gate will close automatically.
z Cancel width / auto-close function of pedestrian mode
*Cancel both width and auto-close function of pedestrian mode:
Please turn on the first
and the second DIP switch (See Fig.8 No.18) to ON position. Press button 4 to open the
gate (see Verify open direction section). Wait for more than 15 sec.. Then press the
same button/button 4 to stop the gate. Wait until the gate close automatically (45 sec.).
Press the same button to stop the gate or the gate will stop automatically at its closed
position if the magnetic limit switch is reached. After this setup is complete, return DIP
switch 1 to OFF position immediately. Thus the width and auto-close function of pedestrian
mode have been canceled.
*Cancel width of pedestrian mode, keep auto-close function of pedestrian mode:
Please
turn on the first and the second DIP switch (See Fig.8 No.18) to ON position. Press button
4 to open the gate (see Verify open direction section). Wait for more than 15 sec.. Then
press the same button/button 4 to stop the gate. Wait some seconds according to your
requirements (1~44 sec.). Then press the same button/button 4 to close the gate, press
the same button again to stop the gate or the gate will stop automatically at its closed
position if the magnetic limit switch is reached. After this setup is complete, return DIP
switch 1 to OFF position immediately. Thus the width of pedestrian mode has been
canceled, the auto-close function of pedestrian mode has been reserved.
Note: the new auto-close time of pedestrian mode has been re-programmed in the device
13