z To erase all existing remote controls, press and hold ‘AN’ button about 14 sec until the
beeper stops ringing. This indicates that all the remote controls have been erased
completely.
z The remote control works in a single channel mode. It has four buttons. The function of
button 1, button 2 and button 3 are the same. With each press of the remote control
button which has been programmed, the gate will open, stop, close or stop cycle.
z Button 1, button 2 and button 3 are used to open or close the gate. Button 4 is available to
set pedestrian mode. Note: if you canceled the pedestrian mode, the function of button 4
is same as the other three buttons.
z Warning: Notify the users that the gate is never to be operated unless it is in full view.
z Verify open direction:
If the gate does not move in the desired direction, then you will need
to reverse the motor operating direction. You can do this by exchanging wires ‘V’ and ‘W’,
‘OP’ and ‘CL’, then insert the wire connector terminal block.
Table 3 DIP switch
(See Fig.8 No.18)
Position Dip Switch Function
ON
Programming / In this position the control board is in
programming condition, NOT USE condition.
1
OFF
Normal / In this position the control board can be
normally used.
ON
Auto-close function and auto-close function of
pedestrian mode are available.
2
OFF
Both Auto-close function and auto-close function of
pedestrian mode are shut off.
ON Limit switch mode is NC.
3
OFF Limit switch mode is NO.
z Set auto-close function (This feature can be selected to make the gate stay open for some
time before it automatically closes. The auto-close time can be adjusted to between 0 and
44 seconds.): please turn on the first and the second DIP switch (See Fig.8 No.18) to ON
position. Press the remote control button (button 1, button 2 or button 3) that has been
programmed to open the gate (see Verify open direction section). Stop the gate at any
position by pressing the same button, wait for some seconds according to your
requirements (the range is 1~44 sec.), this period of time is regarded as ‘auto-close time’.
Close the gate by pressing the same button. Press the button again to stop the gate or the
gate will stop automatically at its closed position if the magnetic limit switch is reached.
After this setup is complete, return DIP switch 1 to OFF position immediately. Thus the
auto-close function has been set.
z Cancel auto-close function:
Please turn on the first and the second DIP switch (See Fig.8
No.18) to ON position. Press the remote control button (button 1, button 2 or button 3) that
has been programmed to open the gate (see Verify open direction section). Stop the
gate at any position by pressing the same button, wait until the gate close automatically
(45 sec.). Press the same button to stop the gate or the gate will stop automatically at its
closed position if the magnetic limit switch is reached. After this setup is complete, return
DIP switch 1 to OFF position immediately. Thus the auto-close function has been
12