User Manual
32
INSTALLATION:
1. Install the mounting plate on a suitable spot
2. Use the included plugs and screws.
3. Now install the detector onto the mounting place.
4. TheLEDwillbrieyilluminate,thedetectorwillemitashortaudiosignal.
5. Youcanperformthersttestbybrieypressingthetestbutton,seealsoparagraph“Testing”.
6. The detector is now functional.
USE:
1. Every40seconds,thegreen“POWER”LEDwillashtoindicatethedetectorisworking.
2. The table below shows when the detector will sound the alarm.
CO concentration
NO ALARM
until after
ALARM
within
33PPM 120 min. -
55PPM 60 min. 90 min.
110PPM 10 min. 40 min.
330PPM - 3 min.
In accordance to the EN 50291-1:2018 standard.
3. When the alarm sounds, it will turn off within 40 seconds after moving the detector to a space with a
CO concentration below 40PPM and without smoke.
4. The alarm sound can temporarily be turned off by pressing the TEST/SILENCE button (only during
smoke detection).
5. Every 40 seconds, the detector will automatically perform an error check.
TEST/SILENCING:
When the detector is working under normal conditions, the sensor and siren should be tested at least every
week. Press the “TEST/SILENCE” button. The device will shortly beep once, then beep three times while
the red LED blinks, then beep four times shortly while the red LED blinks. This indicates the device is OK.
RESET ALARM:
Thealarmcansometimesactivatebecauseofenvironmentalinuences,forexampleduetowatervaporor
dust. You can press the “TEST/SILENCE” button to silence the alarm for 10 minutes.
It is not possible to stop the alarm if CO is detected.
TheredLEDcontinuesashingbutthesirenwillstopfor10minutes.
If there is still smoke detected after 10 minutes, the alarm will continue.
USER MANUAL