Installation Instructions
IntelliGaze™ Reference IntelliGaze™ Installation & Service Manual
Eye Tracking
Parameter
Parameter Default
Value
Description
Log-Type Logfile Determines the output of the logger.
UDP: logs text messages to 127.0.0.1:2351
LogFile location:
/MyDocuments/alea_technologies_gmbh/IntelliGaze/logfiles
Eye-Events Fixation
Duration Min
100 ms The minimum fixation duration of the build in fixation detection
algorithm.
Fixation
Dispersion
60 px The maximum dispersion of the fixation of the build in fixation
detection algorithm
Blink
Duration Min
200 ms The minimum blink duration of the built-in blink detection
algorithm
700 ms The maximum blink duration of the built-in blink detection
algorithm. All blinks longer then this number are regarded as “no
data available”
The Speed Option “Power Saving 1” offers unique power optimization to maximize the battery lifetime on
tablet pcs. It's recommended to use this mode when a tablet pc is operated in a mobile setup without mains
power.
70
Version: 3.0
© alea technologies gmbh, 2015