Owner's Manual

Table Of Contents
ControlsDimensions
TOP VIEW
EXHAUST
AIR
SUPPLY
AIR
OUTSIDE AIR
RETURN AIR
Ø 5” Typ.
(Ø 127 mm)
ACCESS
PANEL
FRONT VIEW
23-1/8”
(587 mm)
16-3/4”
(425 mm)
19”
(483 mm)
2-1/4”
(57 mm)
2-1/4”
(57 mm)
25-3/8”
(645 mm)
Low voltage dry contact (24VAC) for interlock
with heating/cooling systems.
12-3/8”
(314 mm)
SIDE VIEW
Supply
Temperature
Net Airflow
Power
Consumed (W)
Sensible Recovery
Efficiency
Adjusted Sensible
Recovery Efficiency
°F °C CFM L/s
32
0 52 25 44 67% 76%
32 0 64 30 46 65% 72%
32 0 99 47 110 56% 66%
-13 -25 68 32 73 63% 78%
Performance
20 min.
40 min.
60 min.
max
min
MODE
Digital Multifunction Control
(# 611242) and (#611242-FC)
LCD Electronic Multifunction
Control (P/N 611227)
20/40/60 Minute Timer (P/N
611228)
Mode Control
(Recirculation) (P/N 611230)
Speed Control (Low/Intermittent/High)
(P/N 611229)
Project: Architect:
Location: Engineer:
Model #: Contractor:
Quantity: Comments:
Submitted By:
Date:
©2022 American ALDES Ventilation Corporation and ©2022 ALDES Canada. H150-TRG_SPEC-0522. Aldes reserves the right to modify its products at any time to introduce new technologies.
For more information, contact your Aldes sales advisor, visit aldes-na.com, call 1.800.255.7749, or find us on
H150-TRG
Ventilation Performance
External Static Pressure in.w.g. (Pa)
Airow CFM (m
3
/h)
0.7 (175)
0.6 (150)
0.5 (125)
0.4 (100)
0.3 (75)
0.2 (50)
0.1 (25)
0 (0)
0.8 (200)
80 (135)
120 (205)
60 (100)
100 (170)
140 (240)
0.9 (225)
160 (270)