Operating instructions

20
ALT5.INSA 070910-24
ITEM SIZE PART NUMBER
N. America Australia
A 9” X 4 1/2” X 1 1/4” (230 mm x 115 mm x 32 mm) 5096.99 PEHS-12
B 7 1/4” X 4 1/2” X 1 1/4” (184 mm x 115 mm x 32 mm) 245.0 PEHS-61
Alderlea T5 Insert
Firebrick Installation
This package contains 18 full-size rebricks, as well as 1 cut-size brick.
With the heater in the upright position, install rebricks as follows:
- Place rebricks on the bottom of the heater rst. Total of 7 full-size and 1cut
brick.
- Next, install the side rebricks, 4 full-size each side.
- Lastly, install 3 full-size rebricks against the rear wall.
080500-2 WINDBRICK 5055.104