Operation Manual
5
GB
5:1 SET THE DESIRED TEMPERATURE
The temperature can be set between +5°C and +30°C in increments of 0.5°C.
NB. If night or day automation is activated, see section 7:1 point 1 and 2 it is not possible to make tempe-
rature adjustments. The plus and minus symbols are then grey.
1. The temperature displayed is the temperature which is currently set.
2. Increase the temperature by pressing the + button. Reduce the tem-
perature by pressing the – button.
3. The settings are now complete and the boiler will work at the set
temperature.
5:2 DOMESTIC HOT WATER
The Alde boiler stores 8.4 Litres of hot water as standard. If the hot water cylinder is empty, the air is hea-
ted but no damage can result. There are three dierent alternatives for how the boiler can be regulated
depending on need of hot water, no hot water, normal operation and more hot water.
1 kW
+22°C
+22°C
1 kW
1 kW
+22°C
Functions marked with a (*) are accessories, which are not installed on all vehicles, refer to the vehicle
manufacturer’s instructions.
1 kW
+22°C
1. No warm water. If warm water is not needed, press -.
(symbol becomes empty)
NB! If night or day automation is activated, see section 7:1 points 1
and 2 and where hot water is turned o, it is not possible to make
hot water adjustments. The plus and minus symbols are then grey.
2. Normal operation. If there is freshwater in the heater and hot water
is required, press the + button (the symbol will then show half-sha-
ded).
NB! If the 7:1 point 17 Pump operation function has been set to Cont.,
this option cannot be selected.
Info! When hot water only is required, during the summer for instan-
ce, or when there is no requirement for hot water, no settings need
to be made; the boiler looks after this function automatically.
NB! As the hot water and antifreeze in the boiler are heated simulta-
neously, the hot water can be very hot when a high level of heating is
required.
3. More hot water. If you need more hot water, the water temperature
can be temporarily increased to about 70°C. Press the + button so
that the symbol shows fully shaded (black). The boiler returns to
normal operation after 30 minutes. Once you have selected more hot
water, the circulation pump stops. NB. If the 7:1 point 17 Pump ope-
ration function is set at Cont., then the continuous pump operation
function is turned o for 30minutes, but returns thereafter to conti-
nuous pump operation.
If an additional hot water tank (*Alde Flow Art. No. 3020 160) is installed
and the panel is in more hot water mode, continuous hot water is
supplied. The hot water function can then be in operation for longer
than 30 minutes.