Operation Manual
16
16. INSTALLATION INSTRUCTIONS – CONTROL PANEL 3020 HE
Control panel 3020 HE is intended for the Alde Compact 3020 High Eciency.
The control panel should be located at least one metre above the floor, but not too close to the ceiling.
Nor should it be located on an outer wall or close to items which radiate heat, such as a CD player, refri-
gerator or lamps, as this may result in incorrect temperatures. The space behind the panel should be well
ventilated. If the room thermostat on the panel is still aected, an external sensor should be connected to
the panel.
Make a hole for the control panel as shown in Figure C. Screw the control panel securely in place and
push the front cover into position. Secure the cable with clamps to prevent any strain on the terminal
strip of the panel.
15. CABLE CONNECTOR COMPACT 3020 HE AND CONTROL PANEL 3020 HE
Connect accessories to the boiler and control panel as shown in the diagram below.
NB! Do not clamp 12 V cables or sensor cables together with 230 V cables. It is best not to position the
cables close to one another. If the cables are bundled together, there is a greater risk of malfunction
during operation.
Control panel rear
*Truma AC is connected to one of
the TIN Bus connectors.
V-302013 Rev 1445
3020
+
Battery Back-up (3V DC)
Remote Sensor 1
Remote Sensor 2
Sofa
Bed
Heater
TIN Bus
External panel
Fuse 3,15 A
12 V DC
12 V
pump
Control panel
Tin bus
Option board/
Mechanical panel
External
start
Window
sensor
Load
monitor
Outdoor
sensor
D
E
I
F
Circuit board on Compact 3020 HE
Optional board for Compact 3020 HE
Mechanical panel 3010 214
OUT 12V DC
CONNECTED TO
HEATER MAINBOARD
FUSE 3,15 A
EXTRA HOT
WATER PUMP
EIS EX
HEATER
MAINBOARD
12 V DC
+
-
* The automatic climate control functions with:
- Truma Aventa comfort
- Truma Aventa eco
- Truma Saphir comfort RC
- Truma Saphir compact (serial no. > 23091001)
Saphir compact needs a Truma adapter 40090-69300.
C.
B.A.
84 mm
73 mm
R3(4x)
76 mm
87 mm
9 mm
38,5 mm
86 mm
97 mm