Operation Manual

15
GB
13. IMPORTANT INFORMATION
Always switch o the main isolating switch for the boiler when the vehicle is not in use.
When washing the vehicle, do not spray water directly towards the flue.
When camping in winter conditions, ensure the flue and exhaust air valves are kept clear of snow and
ice.
The vehicle may be heated even if the hot water heater is not filled with freshwater.
The LPG boiler and electric element may be operated simultaneously. It does not use more power than
necessary.
Always drain the hot water heater of fresh water when there is a risk of frost and when the vehicle is not
being used.
The LPG boiler must not be in operation when refuelling the vehicle at a garage or similar.
Never allow the heating system to stand empty of ethylene glycol fluid.
NB! Close the main LPG valve in the following circumstances.
When the vehicle is not being used
Depending on national legislation in the country you are in, the main LPG tap must be closed when the ve-
hicle is in trac.
When repairing the boiler.
When leaks in the LPG system are suspected
Closed Open
M
Opening automatic
safety valve/drain valve
K
Opening manual
safety valve/drain valve
R
S
Fluid level
N
14. WARRANTY
Alde’s warranty is valid for two years from date of delivery and is restricted to defects of material or manu-
facture. It is conditional on the boiler having been installed and operated in accordance with the installation
and operating instructions.
NB! The warranty does not cover frost damage.
NB! Only original parts from Alde are to be used as spare parts.
Functions marked with a (*) are accessories, which are not installed on all vehicles, refer to the vehicle