Application Notes 7-19
name in the Data1 column and a one second blink rate into the Data2
column.
App Notes
Now that the rest of the theatre is ready, we start the Recycle sequence
which will get all 12 DVM2s ready. Since we do not know how long it will
be until the first performance, it is necessary to search the DVM2s as fast as
possible. To do this, we start 12 independent search sequences
(SearchTheatre1, SearchTheatre2, SearchTheatre3, SearchPreshow1, etc.)
that turn the corresponding flag “ON” when the player has been searched.
Also, to insure that all outputs will be “OFF” when the Search sequences
begin, we simply turn them all “OFF” before we start Search sequences 1-
12.
If all twelve SelectClip events were put in the same sequence, the time
that it takes for each player to spin-up will accumulate. Even though they
would be scripted to occur on the same frame, the final SelectClip event
could be over 4 minutes late!