Specifications
Page 22 Alcorn McBride Light Cue Pro User’s Guide • July 15, 2010
Parallel Control
Parallel Inputs
Configuration is done
using the
LightCueManager
software.
The Light Cue Pro can be controlled using either contact closures
or voltage inputs on the female DB-37 Control Connector. Up to
12 individual cues can be selected and played, looped, paused, or
stopped.
The configuration is stored on an xml formatted file on the
compact flash card with the name "inputs.cfg."
Voltage or Contact configuration, as well as what cues or cue
names are played, is done via the LightCueManger software.
Pin Connection Pin Connection
1 Input 1 20 Input 1 Return
2 Input 2 21 Input 2 Return
3 Input 3 22 Input 3 Return
4 Input 4 23 Input 4 Return
5 Input 5 24 Input 5 Return
6 Input 6 25 Input 6 Return
7 Input 7 26 Input 7 Return
8 Input 8 27 Input 8 Return
9 Input 9 28 Input 9 Return
10 Input 10 29 Input 10 Return
11 Input 11 30 Input 11 Return
12 Input 12 31 Input 12 Return
13 Input 13 32 Input 13 Return
14 Input 14 33 Input 14 Return
15 Input 15 34 Input 15 Return
16 Input 16 35 Input 16 Return
17 N/C 36 N/C
18 N/C 37 N/C
19 N/C
Parallel inputs should be left disconnected during recording.