Quick Reference Guide

SCRAM CAM
Quick Reference Guide
38
Alerts/Events Description
Bracelet Self-Test
Failure – Replace
Alert
Generated when a battery is installed in the bracelet
and any part of the self test fails. The alert will be re-
generated every 24 hours until the bracelet passes all
facets of the self test.
Bracelet Strap
Closed Alert
Generated when the base station receives the date and
time that the strap was fed through the buckle and
tightened.
Bracelet Strap Open
Alert
Generated when the base station receives the date and
time that the bracelet was cut.
Bracelet Strap
Remains Open Alert
Generated 24 hours after the Bracelet Strap Open alert
is generated. Will be re-generated every 24 hours until
the bracelet straps are replaced.
Detected RF Hacking
Alert
Generated when a client attempts to mimic or “hack”
the RF signal being sent from the bracelet to the base
station.
Extended Pending
Assignment – Base
Station Alert
Generated when the base station is NOT put into the
Assigned to Client status within 24 hours of being put
into the Pending Assignment status.
Extended Pending
Assignment –
Bracelet Alert
Generated when the bracelet is NOT put into the
Assigned to Client status within 24 hours of being put
into the Pending Assignment status.
Failed to Leave Alert Generated when the client does NOT leave the home
by the start time of a “Must Leave” leave window.
Failed to Return
Alert
Generated when the client does NOT return to the
home by the end time of “May Leave” or “Must Leave”
leave window.
Installation
Complete Alert
Generated when all of the installation tasks have been
completed.
Installation
Incomplete Alert
Generated when any of the installation tasks have
NOT been completed. The event will be re-generated
every 24 hours until the installation is successfully
completed.
Late Leave Alert Generated when the client leaves the home after the
start time of a “Must Leave” leave window.
Late Leave with RF
Interference Alert
Generated when the base station detects that the
client has moved outside the authorized range after
the start of a “Must Leave” leave window, but RF
interference may be contributing to that detection.
Late Return Alert Generated when the client returns to the home after
the end of a “May Leave” or “Must Leave” leave
window provided that the client did NOT leave outside
of any authorized leave window. In that case, this alert
would be superseded by the Return from Unauthorized
Leave alert.
Low Base Station
Battery Alert
Generated when the base station’s battery falls below
the operational threshold.
Low Bracelet
Battery Alert
Generated approximately 3 days prior to the expected
failure of the bracelet battery.