Quick Reference Guide
SCRAM CAM
Quick Reference Guide
7
b. Assuming that a bracelet and base station are being
assigned, use the Assign Equipment page to change the
status of both to Pending Assignment.
Note: If a wireless SCRAM Base Station is being used,
the status of that device is immediately set to Assigned to
Client.
c. Print the client’s Participant Agreement.
4. Attach the bracelet to the client.
a. Place the bracelet no more than an index fi nger above the
right or left ankle with the SERIAL NUMBER FACING UP.
b. Feed the strap through the buckle and completely tighten.
The bracelet should be able to be moved slightly, but not
past the shin bone. Be aware that a poorly fi tted bracelet
could have some impact on the bracelet’s ability to take
accurate readings and may result in unneeded time taken to
re-fi t the bracelet.
Important Note: To properly align the bracelet strap,
ensure that the tooth alignment tab is positioned between
two teeth when the buckle is tightened. An “Open Strap
Detected” event will be generated if the strap is not properly
aligned.
c. Tighten the retaining screws until the two sides of the buckle
are fl ush.
5. Log into the Direct Connect application.
a. Open the Direct Connect application.
b. Log into the Direct Connect application using your SCRAM
NET
username and password.
6. Connect the Direct Connect device with your computer.
a. Plug the small (mini-B type) USB connector into the Direct
Connect device.
b. Plug the large (A type) USB connector into a USB port on
your computer.
The
red and blue lights on the Direct Connect device blink
for approximately 5 seconds then both remain on.
Bracelet status in the Direct Connect application: Waiting for
Bracelet.
7. Attach the Direct Connect device to the bracelet.
a. Align the Direct Connect device with the top of the bracelet.
b. Slide the Direct Connect device down over the bracelet.
8. Wake up the bracelet.
a. Momentarily place the magnet on the Direct Connect device
where the word “magnet” appears.
Bracelet status in the Direct Connect application:
Communicating
On the Direct Connect device, the
red light turns off while
the blue light remains on.