Instruction manual

!""#$%&'()*+$,()*(-$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$./0&1$21-3(4*4+$,5-3(6-
3. To keep this setting,
press S2 again and the
display will return to
“Unit”. Pressing S1 now
will change the display to
the next menu item (S1);
continue from step 5.
To change the
measurement units, press
S1. Consecutive pressing
of S1 will change the
units between bAr and
PSI.
When the required unit is
shown, press S2 again
and the display will return
to “Unit”
4. Press S1 to continue to
the next menu item. The
display will show “S1”.
This is switch point 1, the
value of this is the Return
Pressure.
5. Press the S2 button
and the current Return
Pressure setting will be
displayed.
To keep this setting, press S2 several times
until “S1” is displayed again.
Pressing S1 now will change the display to
the next menu item (r1); continue from step
9.
To change the settings, note the
flashing/blinking cursor under the space for
the first digit of Return Pressure setting.
Note:
The display is able to show 4 digit numbers.
In this example a value of 350 bar is shown
and therefore the space for the first digit is
blank. 4 digit numbers are only used if the
measurement units are set to PSI. The
Return Pressure must always be lower
than the Pull Pressure by at least 6.9 bar
(100 psi), to ensure correct Powerig
function
6. Consecutive pressing of S1 will change
the value of the digit over the cursor from 1
to 9 and then 0.
7. When the required value shown, press
S2 and the cursor will move to the right
under the next digit.
8. Continue adjusting each digit in turn.
Pressing S2 after adjusting the last digit will
change the display back to “S1”.
9. Pressing the S1 button
will change the display to
the next menu item.
r1 is the value at which
the Return Pressure (S1),
resets to zero and should
be set at 50 bar (725 psi).
Press S2 to check the
setting. If it is necessary to change the
setting then follow the procedure as in steps
6 & 7.
10 Press S1 to continue
to the next menu item
which is S2.
The S2 & r2 switch points
are not used.
The next steps will save
the settings...
11. Press the S2 button
several times until the
display shows “Stor”.
12. Press the S2 button
and the display will show
“no”. Press the S1 button
to change the display to
“yes”.
13. Press the S2 button to
save the settings. The
display will return to zero.