Instruction manual
Huck-Spin® Series Tooling (HK1076) Alcoa Fastening Systems
7
PULL PRESSURE (PULL CYCLE)
During a typical full‐pressure cycle, with the Huck‐Spin
fastener in place and the collar threaded on, the opera‐
tor positions the tool nose assembly over the fastener
pintail and presses the trigger.
The Huck‐Spin tool Thimble spins onto the pin threads
until limit switch rod senses enough engagement, which
then directs pressurized hydraulic fluid into the chamber
in front of the tool’s piston, forcing it back, and pushing
the nose assembly’s Anvil forward to swage the collar
onto the pin.
RETURN PRESSURE (RETURN CYCLE)
When proper swage presure is reached, the hydraulic
pressure will be redirected to the rear of the Piston, and
the Anvil will automatically eject off the swaged Collar,
and the Thimble counter‐rotates to unscrew from the
pin.
This results in all tool and nose assembly components
returning to their home positions, ready to install the
next fastener.
P
P
RINCIPLE
RINCIPLE
OF
OF
O
O
PERATION
PERATION
4.4
(11.2)
12.6
(32)
13.2
(33.5)
8.9
(22.6)
7.5
(19)
4.7
(12.1)
Inches
(cm)
S
S
PECIFICATIONS
PECIFICATIONS
POWER SOURCE:
Huck POWERIG Hydraulic Unit
HOSE KITS:
Use only genuine HUCK Hose Kits rated @ 10,000
psi working pressure.
MAX OPERATING TEMP:
125° F (51.7° C)
MAX FLOW RATE:
2 gpm (7.6 l/m)
MAX INLET PRESSURE:
5,700 psi (393 BAR)
MAX RETURN PRESSURE:
2,400 psi (165 BAR)
STROKE:
1.808 in. (4.6 cm)
WEIGHT:
17.5 lbs (7.94 kg)
HYDRAULIC FLUID:
ATF meeting DEXRON III, DEXRON IV, MERCON,
Allison C‐4 or equivalent specifications.
Fire resistant hydraulic fluid may also be used,
and is required to comply with OSHA regulation
1926.302 paragraph (d): "the fluid used in
hydraulic power tools shall be fire resistant fluid
approved under schedule 30 of the US Bureau of
Mines, Department of Interior, and shall retain its
operating characteristics at the most extreme
temperatures to which it will be exposed."