Troubleshooting guide
8 — NE maintenance
Alcatel-Lucent 5620 Service Aware Manager 8-37
5620 SAM
System Administrator Guide
13 If the Software Upgrade parameter in the software upgrade policy is deselected,
you must activate the software image. Perform the following steps.
i Edit the following software upgrade policy settings, as described in
Procedure 8-1:
• Deselect the Software Download parameter.
• Select the Software Upgrade parameter.
ii Select the required software image and click Upgrade Sites. The Select Sites
form opens.
iii Use the form to select the required NEs, and then click OK. A dialog box
appears.
iv Ensure that the conditions described in the dialog box are met, and then click
Yes. The software image activation begins.
v Click on the Software Upgrade Status tab to monitor the activation progress.
The Upgrade State displays the following sequence of values:
• Backing Up ISA-AA File—The 5620 SAM makes a backup copy of the
isa-aa.tim file in the primary-image location specified by the BOF.
• Updating ISA-AA File—The new isa-aa.tim file is downloaded to the
primary-image location specified by the BOF, and the appropriate ISA-AA
upgrade command is issued on each NE.
• Pending ISA MDA Reboot—A reboot of the ISA-AA MDA is required.
14 Perform the following steps on each upgraded ISA-AA MDA to shut down and reboot
the MDA.
i Choose Equipment from the network navigation tree view selector. The
network navigation tree displays the Equipment view.
ii Navigate to the upgraded ISA-AA MDA. The path is
Network→NE→Shelf→Card Slot n→Daughter Card Slot n.
iii Right-click on the Daughter Card Slot object and choose Shut Down. A dialog
box appears.
iv Click View Dependencies. A dialog box displays the number of objects that
shutting down the ISA-AA MDA may affect.
v Click OK.
vi When you are certain that shutting down the MDA has no unintended effects,
select the check box and click Yes. The 5620 SAM shuts down the ISA-AA MDA.
vii Right-click on the Daughter Card Slot object and choose Reboot. A dialog box
appears.
Note — Alternatively, you can select the required ISA-AA image on the
Software Images tab and click Activate Image.
Release 12.0 R6 | November 2014 | 3HE 08861 AAAF TQZZA Edition 01