Troubleshooting guide
7 — 5620 SAM system redundancy
Alcatel-Lucent 5620 Service Aware Manager 7-13
5620 SAM
System Administrator Guide
Collocated system, primary station unreachable
Figure 7-11 shows a collocated system in which the station that hosts the primary
server and database is unreachable.
Figure 7-11 Primary server and database station down, collocated system
The following occur when the primary station becomes unresponsive:
• The standby server and database become the primary server and database.
• Redundancy is restored when the former primary station returns to service as the
standby station.
Distributed system, primary server unreachable
Figure 7-12 shows a distributed system in which the primary server is unreachable.
Figure 7-12 Primary server unreachable, distributed system
Workstation
down
Activity switch
Rebuild as standby
server and database
24116
Collocated primary
server/database
Becomes primary main
server and database
Collocated standby
server/database
Failover
Managed
network
Primary database
Primary main
server
Standby database
Standby main
server
Connectivity
loss
24117
Station
down
Managed
network
Release 12.0 R6 | November 2014 | 3HE 08861 AAAF TQZZA Edition 01